The aim of the present study was to evaluate magnetic resonance venography (MRV) scanned by breath-hold volume interpolated body examination with spectral fat saturation (VIBE-fs), combined with Dixon fat-suppressed VIBE (VIBE-Dixon) by using a 1.5T MR scanner for detecting deep venous thrombosis (DVT) compared with duplex sonography. A total of 31 patients with DVT were identified using duplex sonography and were enrolled in the present study for MRV examination, from the inferior vena cava to the ankle level after injection of gadopentetate dimeglumine. Venous segment-to-segment comparison was assessed for DVT detection between MRV and duplex sonography. A total of two radiologists separately performed subjective image quality assessment using a 5-point scale. Cohen's κ coefficient, Wilcoxon rank sum test and intraclass correlation coefficient values were used for statistical analysis. Of the 303 evaluated vein segments, duplex sonography identified 119 (39.3%; 119/303) venous segments with thrombus, while MRV detected 170 (56.1%; 170/303) venous segments with thrombus. The diagnostic agreement rate of DVT between duplex sonography and MRV was poor in the deep femoral vein and anterior tibial veins, while it was excellent in the inferior vena cava (IVC), common iliac vein, external iliac vein, femoral vein, popliteal vein, posterior tibial veins and peroneal veins. In addition, poor reliability was detected in the deep femoral vein, anterior tibial veins and peroneal veins, but good to excellent reliability was observed in IVC, common iliac vein, external iliac vein, femoral vein, popliteal vein and posterior tibial veins. Furthermore, image quality scores of each venous segment between the two radiologists indicated no statistical difference. Therefore, MRV scanned using VIBE-fs for the suprainguinal and VIBE-Dixon for the infrainguinal region may be a useful method for detecting DVT compared with duplex sonography. The results of present study proved this MR protocol to be a beneficial alternative imaging modality for the detection of DVT when duplex sonography is inadequate or not able to be performed.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7086293 | PMC |
http://dx.doi.org/10.3892/etm.2020.8500 | DOI Listing |
Acta Radiol
January 2025
Department of Radiology, Interventional Radiology, Sağlık Bilimleri Üniversitesi Ankara Dışkapı Yıldırım Beyazıt Eğitim ve Araştırma Hastanesi, Ankara, Türkiye.
Background: Carotid artery stenting (CAS) is an interventional management in preventing ischemic stroke caused by carotid artery stenosis. After the treatment with CAS, in-stent restenosis caused by neointimal hyperplasia may develop.
Purpose: This study aims to obtain a better determination of neointimal hyperplasia using superb microvascular imaging (SMI), which provides a high-quality visualization of the endoluminal lesions, and to compare these results with B-mode and Doppler ultrasound (US).
Int J Surg Case Rep
January 2025
Introduction And Importance: True brachial artery aneurysms are rather uncommon, due to their number of etiological factors. Besides inducing symptoms such as hand or digit ischemia, they may present as pulsative tumefactions and cause pain or paresthesias through nerve impingement. The diagnosis is based on duplex ultrasonography, CTA in the operational planning phase, and a physical examination.
View Article and Find Full Text PDFExp Physiol
January 2025
Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Dallas, Dallas, Texas, USA.
A reduction in cerebral blood flow (CBF) has been observed during spaceflight and bed rest. We aimed to examine the magnitude and regional heterogeneity of the decrease in CBF during bed rest compared to posture changes on Earth. Seventeen participants (age, 29 ± 9 years, 7 females) were studied in the upright and supine posture and over 3 days of bed rest.
View Article and Find Full Text PDFCurr Med Imaging
January 2025
UOC Neurologia e Rete Stroke Metropolitana, Istituto delle Scienze Neurologiche di Bologna, Italy.
Transcranial Doppler is an instrumental ultrasound method capable of providing data on various brain pathologies, in particular, the study of cerebral hemodynamics in stroke, quickly, economically, and with repeatability of the data themselves. However, literature reviews from clinical studies and clinical trials reported that it is an operator-dependent method, and the data can be influenced by external factors, such as noise, which may require greater standardization of the parameters. Artificial intelligence can be utilized on transcranial Doppler to increase the accuracy and precision of the data collected while decreasing operator dependencies.
View Article and Find Full Text PDFBMJ Open
December 2024
Department of Vascular Surgery, Leids Universitair Medisch Centrum, Leiden, The Netherlands.
Introduction: Foot ulcers are one of the most serious complications of diabetes, leading to significant risks on amputation and mortality. Peripheral arterial disease (PAD) is an important factor for the development and the outcome of diabetic foot ulcers (DFU). Although prompt and accurate detection of PAD is critical to reduce complications, its diagnosis can be challenging with currently used bedside tests (such as ankle-brachial index and toe pressure) due to medial arterial calcification.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!