A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Zwitterionic carboxybetaine polymers extend the shelf-life of human platelets. | LitMetric

Zwitterionic carboxybetaine polymers extend the shelf-life of human platelets.

Acta Biomater

Department of Chemical Engineering, University of Washington, Seattle, WA 98195, USA; Department of Bioengineering, University of Washington, Seattle, WA 98195, USA. Electronic address:

Published: June 2020

The shelf-life of human platelets preserved in vitro for therapeutic transfusion is limited because of bacterial contamination and platelet storage lesion (PSL). The PSL is the predominant factor and limiting unfavorable interactions between the platelets and the non-biocompatible storage bag surfaces is the key to alleviate PSL. Here we describe a surface modification method for biocompatible platelet storage bags that dramatically extends platelet shelf-life beyond the current US Food and Drug Administration (FDA) standards of 5 days. The surface coating of the bags can be achieved through a simple yet effective dip-coating and light-irradiation method using a biocompatible polymer. The biocompatible polymers with tunable functional groups can be routinely fabricated at any scale and impart super-hydrophilicity and non-fouling capability on commercial hydrophobic platelet storage bags. As critical parameters reflecting the platelets quality, the activation level and binding affinity with von Willebrand factor (VWF) of the platelets stored in the biocompatible platelet bags at 8 days are comparable with those in the commercial bags at 5 days. This technique also demonstrates promise for a wide range of medical and engineering applications requiring biocompatible surfaces. STATEMENT OF SIGNIFICANCE: Current standard platelet preservation techniques agitate platelets at room temperature (20-24 °C) inside a hydrophobic (e.g., polyvinyl chloride (PVC)) storage bag, thereby allowing preservation of platelets only for 5 days. A key factor leading to quality loss is the unfavorable interaction between the platelets and the non-biocompatible storage bag surfaces. Here, a surface modification method for biocompatible platelet storage bags has been created to dramatically extend platelet shelf-life beyond the current FDA standards of 5 days. The surface coating of the bags can be achieved via a simple yet effective dip-coating and light-irradiation method using a carboxybetaine polymer. This technique is also applicable to many other applications requiring biocompatible surfaces.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.actbio.2020.03.032DOI Listing

Publication Analysis

Top Keywords

platelet storage
16
storage bag
12
method biocompatible
12
biocompatible platelet
12
storage bags
12
shelf-life human
8
platelets
8
human platelets
8
platelet
8
platelets non-biocompatible
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!