Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The objective of this study was to compare safety and efficacy of patent foramen ovale (PFO) closure compared with medical therapy in patients with cryptogenic stroke (CS).
Background: The role of PFO closure in preventing recurrent stroke in patients with prior CS has been controversial.
Methods: We searched PubMed, EMBASE, the Cochrane Central Register of Controlled trials, and the clinical trial registry maintained at clinicaltrials.gov for randomized control trials that compared device closure with medical management and reported on subsequent stroke and adverse events. Event rates were compared using a forest plot of relative risk using a random-effects model assuming interstudy heterogeneity.
Results: A total of 6 studies (n = 3747) were included in the final analysis. Mean follow-up ranged from 2 to 5.9 years. Pooled analysis revealed that device closure compared to medical management was associated with a significant reduction in stroke (risk ratio [RR] = 0.41, 95% CI = 0.20-0.83, I = 51%, P = 0.01). There was, however, a significant increase in atrial fibrillation with device therapy (RR = 5.29, 95% CI = 2.32-12.06, I = 38%, P < 0.0001). No effect was observed on major bleeding (P = 0.50) or mortality (P = 0.42) with device therapy. Subgroup analyses showed that device closure significantly reduced the incidence of the composite primary end point among patients who had large shunt sizes (RR = 0.35, 95% CI = 0.18-0.68, I = 27%, P = 0.002). The presence/absence of atrial septal aneurysm (P = 0.52) had no effect on the outcome.
Conclusion: PFO closure is associated with a significant reduction in the risk of stroke compared to medical management. However, it causes an increased risk of atrial fibrillation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7136357 | PMC |
http://dx.doi.org/10.1016/j.ihj.2019.10.002 | DOI Listing |