Clinician scientists are physicians who are uniquely trained to bridge the gap between scientific discovery and clinical practice. However, the challenges of integrating research and medicine are often not directly addressed in the clinician scientist training programs. Furthermore, the demanding training path is financially and personally daunting. Previous studies have shown that MD/PhD trainees value the advice and expertise of senior mentors in navigating their academic career path. Despite this demand for mentors, there is a lack of formal mentorship initiatives at the institutional level across Canada. Recently, MD/PhD trainees have attempted to address this issue by implementing a nationwide mentorship match, with the aim of making mentorship more accessible to trainees across Canada.

Download full-text PDF

Source
http://dx.doi.org/10.25011/cim.v43i1.33649DOI Listing

Publication Analysis

Top Keywords

clinician scientist
8
mentorship match
8
md/phd trainees
8
piloting long
4
long distance
4
distance clinician
4
scientist trainee
4
mentorship
4
trainee mentorship
4
match canada
4

Similar Publications

Purpose: Especially in Europe, amino acid PET is increasingly integrated into multidisciplinary neuro-oncological tumor boards (MNTBs) to overcome diagnostic uncertainties such as treatment-related changes. We evaluated the accuracy of MNTB decisions that included the O-(2-[18F]-fluoroethyl)-L-tyrosine (FET) PET information compared with FET PET results alone to differentiate tumor relapse from treatment-related changes.

Patients And Methods: In a single academic center, we retrospectively evaluated 180 MNTB decisions of 151 patients with CNS WHO grade 3 or 4 gliomas (n = 122) or brain metastases (n = 29) presenting equivocal MRI findings following anticancer treatment.

View Article and Find Full Text PDF

Background: Diabetic myocardial disorder (DbMD, evidenced by abnormal echocardiography or cardiac biomarkers) is a form of stage B heart failure (SBHF) at high risk for progression to overt HF. SBHF is defined by abnormal LV morphology and function and/or abnormal cardiac biomarker concentrations.

Objective: To compare the evolution of four DbMD groups based on biomarkers alone, systolic and diastolic dysfunction alone, or their combination.

View Article and Find Full Text PDF

Objectives: Mentorship supports faculty to succeed in their careers with confidence, resilience, and satisfaction. To address inequities evident with an informal approach, a formal mentorship program was designed and implemented.

Methods: The Quality Implementation Framework (QIF) was applied.

View Article and Find Full Text PDF

Audiovisual Breathing Guidance for Improved Image Quality and Scan Efficiency of T2- and Diffusion-Weighted Liver MRI.

Invest Radiol

January 2025

From the Department of Diagnostic and Interventional Radiology, University Hospital Bonn, Bonn, Germany (N.M., A.I., A.L., L.B., T.D., D. Kravchenko, D. Kuetting, C.C.P., J.A.L.); Quantitative Imaging Lab Bonn (QILaB), Bonn, Germany (N.M., A.I., L.B., D. Kravchenko, D. Kuetting, J.A.L.); Philips Healthcare, Hamburg, Germany (C.K.); Philips Medical Systems, Eindhoven, the Netherlands (A.H.-M.); and Department of Diagnostic and Interventional Radiology, University Hospital Aachen, Aachen, Germany (C.Y.).

Objectives: Impaired image quality and long scan times frequently occur in respiratory-triggered sequences in liver magnetic resonance imaging (MRI). We evaluated the impact of an in-bore active breathing guidance (BG) application on image quality and scan time of respiratory-triggered T2-weighted (T2) and diffusion-weighted imaging (DWI) by comparing sequences with standard triggering (T2S and DWIS) and with BG (T2BG and DWIBG).

Materials And Methods: In this prospective study, random patients with clinical indications for liver MRI underwent 3 T MRI with standard and BG acquisitions.

View Article and Find Full Text PDF

Enhancing safety in CT-guided lung biopsies: correlation of MinIP imaging with pneumothorax risk prediction.

Insights Imaging

January 2025

Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.

Objectives: This study aimed to evaluate whether minimum-intensity projection (MinIP) images could predict complications in CT-guided lung biopsies.

Methods: We retrospectively analyzed 72 procedures from January 2019 to December 2023, categorizing patients by pneumothorax and the severity of hemorrhage (grade 2 or higher). Radiodensity measurements were performed using lung window (LW) and MinIP (10-mm slab) images.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!