Background: Routine TEP technique requires three skin incisions for placement of three trocars in the midline. Otherwise, this can be done by three-port triangular technique or two-hand technique. This study reports a randomised trial of perioperative outcomes and ergonomics characteristics of this procedure using two different techniques of port insertion.

Methods: N = 28 patients were randomised into two groups for triangular three-port (TTEP) versus midline three-port TEP (MTEP) hernioplasty after informed written consent in Department of Surgery, King George's Medical University UP between September 2016 and September 2017 after institutional ethical approval. Patient-related outcomes in terms of quality of life (QOL) and ergonomic evaluation of the technique were compared in double-blinded fashion.

Results: Postoperative pain score at 24 h post surgery (5.1 ± 0.6; 95% CI 4.9-5.3 vs. 4.8 ± 0.4; 95% CI 4.6-4.9) differed, while hospital stay, time to return to routine work, tolerance to oral feeds and intraoperative complications occurrence (OR 2.1; 95% CI 0.2-24.3) were comparable in both groups. Time to return to office work (5.5 ± 0.5; 95% CI 5.4-5.7 vs. 4.0 ± 0.8; 95% CI 3.7-4.3) and immediate postoperative sensation of mesh and pain score were significantly higher in MTEP compared to TTEP. Ergonomic parameters including visualization of landmark score, spreading of mesh score and total surgeon satisfaction score (TTEP 8.4 ± 0.7; 95% CI 8.1-8.6 vs. MTEP 7.0 ± 0.8; 95% CI 6.7-7.3), mental effort quotient (SMEQ score: TTEP 50.6 ± 12.7; 95% CI 45.9-55.3 vs. MTEP 70.8 ± 12.6: 95% CI 66.1-75.4) and physical effort quotient (LEDQ scores in wrist, hand, arm and shoulders) were also superior in triangular technique of port placement.

Conclusion: Triangular three-port TEP hernioplasty is ergonomically feasible and enables a surgeon to perform surgery safely using basic principles of laparoscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00464-020-07525-4DOI Listing

Publication Analysis

Top Keywords

95%
9
perioperative outcomes
8
versus midline
8
midline three-port
8
triangular technique
8
triangular three-port
8
three-port tep
8
pain score
8
time return
8
score ttep
8

Similar Publications

Article Synopsis
  • The study measured fibrinogen fluorescence at temperatures between 20 and 80 degrees Celsius across different pH levels.
  • It was found that raising the temperature from 20 to 40 degrees Celsius did not change the structure of fibrinogen in solutions with pH between 4.5 and 9.3.
  • However, temperatures between 40 to 50 degrees Celsius caused some structural changes in neutral solutions, and temperatures above 50-55 degrees Celsius led to significant denaturation of the fibrinogen molecule.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!