Evaluating users' experiences of electronic prescribing systems in relation to patient safety: a mixed methods study.

BMC Med Inform Decis Mak

NIHR Imperial Patient Safety Translational Research Centre, Imperial College London, London, W2 1PE, UK.

Published: April 2020

Background: User interface (UI) design features such as screen layout, density of information, and use of colour may affect the usability of electronic prescribing (EP) systems, with usability problems previously associated with medication errors. To identify how to improve existing systems, our aim was to explore prescribers' perspectives of UI features of a commercially available EP system, and how these may affect patient safety.

Methods: Two studies were conducted, each including ten participants prescribing a penicillin for a test patient with a penicillin allergy. In study 1, eye-gaze tracking was used as a means to explore visual attention and behaviour during prescribing, followed by a self-reported EP system usability scale. In study 2, a think-aloud method and semi-structured interview were applied to explore participants' thoughts and views on prescribing, with a focus on UI design and patient safety.

Results: Study 1 showed high visual attention toward information on allergies and patient information, allergy pop-up alerts, and medication order review and confirmation, with less visual attention on adding medication. The system's usability was rated 'below average'. In study 2, participants highlighted EP design features and workflow, including screen layout and information overload as being important for patient safety, benefits of EP systems such as keeping a record of relevant information, and suggestions for improvement in relation to system design (colour, fonts, customization) and patient interaction.

Conclusions: Specific UI design factors were identified that may improve the usability and/or safety of EP systems. It is suggested that eye-gaze tracking and think-aloud methods are used in future experimental research in this area. Limitations include the small sample size; further work should include similar studies on other EP systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7126479PMC
http://dx.doi.org/10.1186/s12911-020-1080-9DOI Listing

Publication Analysis

Top Keywords

visual attention
12
electronic prescribing
8
prescribing systems
8
patient safety
8
design features
8
screen layout
8
eye-gaze tracking
8
patient
7
systems
6
prescribing
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!