Occlusal analysis is a substantial tool for the functional improvement evaluation after using implant-retained overdenture comparing to complete denture without dental implant retaining. To evaluate occlusal pattern, chewing force distribution in mini-dental implant-retained mandibular overdentures by computerised occlusal analysis system and to compare patient satisfaction after 1-year function. Thirty-one patients wearing complete dentures were included in the study. Prior to mini-dental implant-retained treatment, all patients were assessed for occlusion and force distribution using computerised occlusal analysis system (T-Scan ), and then, all patients received two mini-dental implant-retained mandibular overdentures. Mini-dental implants were immediately loaded using low vertical profile attachments (Equator ). T-Scan was used to evaluate chewing force and force distribution at 1 day, 3 months, 6 months and 12 months. The patient satisfactions before implant placement and after 1 year were evaluated using questionnaires which included satisfaction of denture quality, psychosocial behaviour and chewing efficiency modified from the validated questionnaires. Clinical evaluation of two mini-dental implant-retained mandibular overdentures showed 100% success rate after 1 year. T-Scan demonstrated that maximum occlusal contact force increased continuously. The force distribution; the tooth contact number increased over the period. At 1-year follow-up, overall patient satisfaction was significantly greater than before receiving mini-dental implant treatment (P < .001). Using computerised occlusal analysis, mini-dental implants improve complete denture function significantly in terms of maximum occlusal contact force, tooth contact number without the impairment of force distribution. The oral function of the patients has been enhanced.

Download full-text PDF

Source
http://dx.doi.org/10.1111/joor.12969DOI Listing

Publication Analysis

Top Keywords

mini-dental implant-retained
20
occlusal analysis
16
implant-retained mandibular
16
mandibular overdentures
16
force distribution
16
computerised occlusal
12
chewing force
8
analysis system
8
patient satisfaction
8
mini-dental
7

Similar Publications

Unlabelled: This prospective clinical study aimed to assess self-reported orofacial esthetics, chewing function, and oral health-related quality of life (OHRQoL) over three years in the Kennedy Class I patients without posterior dentition who received free-end saddle removable partial dentures (RPDs) retained by two mini dental implants (MDIs) inserted in the canine/first premolar region. The study's robust findings reaffirm the viability of MDI-retained RPDs as a treatment modality in contemporary prosthodontics, instilling confidence in the dental community.

Materials And Methods: 92 participants with posterior edentulism in the maxilla or mandible received 184 MDIs and 92 RPDs.

View Article and Find Full Text PDF

This study presents the first 10-year follow-up investigation of the implant survival and peri-implant outcomes of one-piece mini dental implants (MDIs) retaining mandibular implant overdentures (IODs), including marginal bone level alterations (ΔMBLs), clinical peri-implant parameters, and complications. Twenty participants with horizontally atrophied mandibles received complete dentures and four MDIs (diameter 1.8 mm) at baseline.

View Article and Find Full Text PDF

Use of mini implants for the two-implant retained mandibular overdenture: A prospective study.

Med J Armed Forces India

December 2023

Associate Professor & Instructor, (Dental Surgery & Oral Health Sciences), Armed Forces Medical College, Pune, India.

Background: The two-implant retained mandibular overdenture utilizing nonsplinted implants is a proven treatment modality for completely edentulous patients. However, a lacuna still exists regarding the suitability of mini dental implants for this purpose. The purpose of the study was to evaluate implant stability and crestal bone loss in single-piece mini dental implants loaded with immediate or conventional loading protocols to retain a mandibular overdenture.

View Article and Find Full Text PDF

Aim: To compare the long-term prospective clinical outcomes in a previous randomized controlled clinical trial (RCT) of 2 Mini Dental Implant (2MDI), 4 Mini Dental Implant (4MDI), and 2 Conventional Dental Implant (2CDI)-retained mandibular overdenture with follow-up between 5 to 8 years.

Materials And Methods: Thirty-seven patients formerly participated in the Comparative Clinical Study of CDI and MDI for Mandibular Overdenture were requested for examination of clinical outcomes. A total of 104 implants were placed with mean follow-up periods 6.

View Article and Find Full Text PDF

Purpose: Mini-dental implants (MDIs) have been used to support and retain overdentures, providing patients with a less invasive placement procedure. Although lucrative, the use of MDIs to retain a maxillary overdenture is still not an established treatment modality. This systematic review aims to answer the question: Do mini-implant-retained maxillary overdentures provide a satisfactory treatment outcome for complete edentulism?

Methods: A systematic search for relevant articles was conducted to include articles published until April 2021 in the following electronic databases: CINAHL, Cochrane, EMBASE, PubMed, and Web of Science.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!