Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.12968/hmed.2019.0344 | DOI Listing |
J Binocul Vis Ocul Motil
January 2025
Eye Center, Sanno Hospital, Tokyo, Japan.
Purpose: To investigate changes in eye alignment before and after ICL implantation in patients with myopia having corrected distance visual acuity (CDVA) of ≥0.0 logMAR.
Subjects And Methods: The medical records of 1012 patients without eye movement limitation who underwent bilateral ICL implantation were retrospectively reviewed a at the Eye Center of Sanno Hospital in Japan.
Can J Ophthalmol
January 2025
Department of Ophthalmology, Sheba Medical Center of Israel, Israel; Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
Objective: Adults who undergo strabismus surgery, in addition to cosmesis, could benefit from improved stereopsis. This improvement is associated with the performance of motor skill tasks in young adults; they reduce the risk of tripping or falling during everyday locomotion and improve reading efficiency. This study aimed to assess stereopsis level after strabismus surgery in adults who underwent strabismus surgery for any reason.
View Article and Find Full Text PDFJ Family Med Prim Care
December 2024
Department of Ophthalmology, North Eastern Indira Gandhi Regional Institute of Health and Medical Sciences (NEIGRIHMS), Shillong, Meghalaya, India.
Purpose: To determine the clinical pattern and burden of strabismus in a teaching institute of Northeast (NE) India.
Methods: In this hospital-based, cross-sectional study, detailed clinical evaluation of patients with manifest strabismus was carried out for a period of one and half years.
Results: Out of the 7222 new outpatient department attendances, a total of 110 new patients with manifest strabismus were found, with a hospital-based burden of 1.
Digit Health
December 2024
Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing Key Laboratory of Ophthalmology & Visual Sciences, Capital Medical University, Beijing, China.
Background: To explore the accuracy of VR technology for strabismus screening.
Methods: In this cross-sectional study, a total of 191 subjects were included. Examinations included VR technology based on infrared, the cover-uncover test, and the prism alternating cover test (PACT) at various gaze positions, specifically at distances of 33 cm and 6 m.
Vestn Oftalmol
November 2024
Krasnov Research Institute of Eye Diseases, Moscow, Russia.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!