A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Frequency-dependent signal and noise in spectroscopic x-ray imaging. | LitMetric

Frequency-dependent signal and noise in spectroscopic x-ray imaging.

Med Phys

Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario, Canada.

Published: July 2020

Purpose: We present a new framework for theoretical analysis of the noise power spectrum (NPS) of photon-counting x-ray detectors, including simple photon-counting detectors (SPCDs) and spectroscopic x-ray detectors (SXDs), the latter of which use multiple energy thresholds to discriminate photon energies.

Methods: We show that the NPS of SPCDs and SXDs, including spatio-energetic noise correlations, is determined by the joint probability density function (PDF) of deposited photon energies, which describes the probability of recording two photons of two different energies in two different elements following a single-photon interaction. We present an analytic expression for this joint PDF and calculate the presampling and digital NPS of CdTe SPCDs and SXDs. We calibrate our charge sharing model using the energy response of a cadmium zinc telluride (CZT) spectroscopic x-ray detector and compare theoretical results with Monte Carlo simulations.

Results: Our analysis shows that charge sharing increases pixel signal-to-noise ratio (SNR), but degrades the zero-frequency signal-to-noise performance of SPCDs and SXDs. In all cases considered, this degradation was greater than 10%. Comparing the presampling NPS with the sampled NPS showed that degradation in zero-frequency performance is due to zero-frequency noise aliasing induced by charge sharing.

Conclusions: Noise performance, including spatial and energy correlations between elements and energy bins, are described by the joint PDF of deposited energies which provides a method of determining the photon-counting NPS, including noise-aliasing effects and spatio-energetic effects in spectral imaging. Our approach enables separating noise due to x-ray interactions from that associated with sampling, consistent with cascaded systems analysis of energy-integrating systems. Our methods can be incorporated into task-based assessment of image quality for the design and optimization of spectroscopic x-ray detectors.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7496729PMC
http://dx.doi.org/10.1002/mp.14160DOI Listing

Publication Analysis

Top Keywords

spectroscopic x-ray
16
x-ray detectors
12
spcds sxds
12
pdf deposited
8
joint pdf
8
charge sharing
8
noise
6
x-ray
6
nps
6
frequency-dependent signal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!