Background: Acute respiratory infections (ARIs), primarily pneumonia, are the leading infectious cause of under-5 mortality worldwide. Manually counting respiratory rate (RR) for 60 seconds using an ARI timer is commonly practiced by community health workers to detect fast breathing, an important sign of pneumonia. However, correctly counting breaths manually and classifying the RR is challenging, often leading to inappropriate treatment. A potential solution is to introduce RR counters, which count and classify RR automatically.
Objective: This study aims to determine how the RR count of an Automated Respiratory Infection Diagnostic Aid (ARIDA) agrees with the count of an expert panel of pediatricians counting RR by reviewing a video of the child's chest for 60 seconds (reference standard), for children aged younger than 5 years with cough and/or difficult breathing.
Methods: A cross-sectional study aiming to enroll 290 children aged 0 to 59 months presenting to pediatric in- and outpatient departments at a teaching hospital in Addis Ababa, Ethiopia, was conducted. Enrollment occurred between April and May 2017. Once enrolled, children participated in at least one of three types of RR evaluations: (1) agreement-measure the RR count of an ARIDA in comparison with the reference standard, (2) consistency-measure the agreement between two ARIDA devices strapped to one child, and (3) RR fluctuation-measure RR count variability over time after ARIDA attachment as measured by a manual count. The agreement and consistency of expert clinicians (ECs) counting RR for the same child with the Mark 2 ARI timer for 60 seconds was also measured in comparison with the reference standard.
Results: Primary outcomes were (1) mean difference between the ARIDA and reference standard RR count (agreement) and (2) mean difference between RR counts obtained by two ARIDA devices started simultaneously (consistency).
Conclusions: Study strengths included the design allowing for comparison between both ARIDA and the EC with the reference standard RR count. A limitation is that exactly the same set of breaths were not compared between ARIDA and the reference standard since ARIDA can take longer than 60 seconds to count RR. Also, manual RR counting, even when aided by a video of the child's chest movements, is subject to human error and can result in low interrater reliability. Further work is needed to reach global consensus on the most appropriate reference standard and an acceptable level of agreement to provide ministries of health with evidence to make an informed decision on whether to scale up new automated RR counters.
Trial Registration: ClinicalTrials.gov NCT03067558; https://clinicaltrials.gov/ct2/show/NCT03067558.
International Registered Report Identifier (irrid): RR1-10.2196/16531.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7163412 | PMC |
http://dx.doi.org/10.2196/16531 | DOI Listing |
Front Parasitol
May 2024
Department of Parasitology, Leiden University Medical Center, Leiden, Netherlands.
Detection of spp. DNA in gynaecological samples by quantitative real-time polymerase chain reaction (qPCR) is considered to be the reference diagnostic test for female genital schistosomiasis (FGS). However, qPCR needs expensive laboratory procedures and highly trained technicians.
View Article and Find Full Text PDFFront Parasitol
February 2024
National Reference Center for Parasitology, Research Institute of the McGill University Center, Montreal, QC, Canada.
The Polymerase Chain Reaction (PCR) test is a highly sensitive, specific, and rapid diagnostic tool for Chagas disease. Chagas disease is caused by the protozoan flagellate and is endemic to the Americas. While conventional serological methods are still used in the diagnosis of Chagas disease, they are being gradually replaced by molecular methods like PCR.
View Article and Find Full Text PDFACS Pharmacol Transl Sci
January 2025
Department of Medicinal Chemistry and Institute for Translational Neuroscience, University of Minnesota, Minneapolis, Minnesota 55455, United States.
Opioid agonist ligands bind opioid receptors and stimulate downstream signaling cascades for various biological processes including pain and reward. Historically, before cloning the receptors, muscle contraction assays using isolated organ tissues were used followed by radiolabel ligand binding assays on native tissues. Upon cloning of the opioid G protein-coupled receptors (GPCRs), cell assays using transfected opioid receptor DNA plasmids became the standard practice including S-GTPγS functional and cAMP based assays.
View Article and Find Full Text PDFAm J Hum Biol
January 2025
Department of Public Health Dentistry, Tamilnadu Govt Dental College, Chennai, India.
Objectives: This study aimed to determine the sequence and eruption chronology of permanent teeth in school children and adolescents of Chennai and compare the findings with an existing standard table. Additionally, the study also attempted to explore the influence of sex, body mass index (BMI), and socioeconomic status (SES) on tooth eruption patterns.
Methods: A cross-sectional study was designed, and 12,650 children aged 5-18 years were selected from thirty-five schools using a multistage random sampling method.
ALTEX
January 2025
National Institutes of Health, National Institute for Environmental Health Sciences, DTT/NICEATM, Durham, NC, USA.
The integration of artificial intelligence (AI) into new approach methods (NAMs) for toxicology rep-resents a paradigm shift in chemical safety assessment. Harnessing AI appropriately has enormous potential to streamline validation efforts. This review explores the challenges, opportunities, and future directions for validating AI-based NAMs, highlighting their transformative potential while acknowledging the complexities involved in their implementation and acceptance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!