Background and purpose - The introduction of new total hip replacements (THRs) is known to be associated with an increased risk for complications. On completion of a competitive procurement process, a new uncemented cup system was introduced into general use at our institution in 2016. We launched this study after the introduction to assess (1) the incidence of early dislocations of the old (Pinnacle) and the new (Continuum) cup systems, and (2) whether the cup design would affect the risk for dislocation.Patients and methods - We assessed the incidence of dislocations after 1,381 primary THRs performed at our institution during 2016. Also, the effect of the cup system (Pinnacle, Continuum with neutral liner, Continuum with elevated rim liner) on dislocation rates was analyzed using a multivariable regression model.Results - 47 (3.4%) early dislocations were identified. The incidence of dislocations was 1.3% for the Pinnacle, 5.1% for the Continuum with neutral liner, and 1.2% for the Continuum with elevated rim liner. The Continuum with neutral liner was found to have an increased risk for dislocations compared with the Pinnacle (aOR 5, 95% CI 1.4-17). However, when an elevated rim liner was used with the Continuum, the risk for dislocation between the Continuum and the Pinnacle was similar.Interpretation - Our results emphasize the need for both careful consideration before the introduction of new implants and the systematic monitoring of early outcomes thereafter. The elevated rim liner should be preferred for use with the Continuum cup because of the poor coverage of the neutral liner that may result in dislocations.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8023946 | PMC |
http://dx.doi.org/10.1080/17453674.2020.1744981 | DOI Listing |
Acta Orthop
October 2024
Faculty of Medicine and Health Technology, Tampere University, Tampere; Coxa Hospital for Joint Replacement, Tampere, Finland.
SICOT J
September 2024
Academic Orthopaedic Department, Aristotle University Medical School, General Hospital Papageorgiou, Ring Road Efkarpia, Thessaloniki 56403, Greece - Centre of Orthopaedic and Regenerative Medicine (CORE), Center for Interdisciplinary Research and Innovation (CIRI)-Aristotle University of Thessaloniki (AUTH), Balkan Center, Buildings A & B, 10th km Thessaloniki-Thermi Rd, P.O. Box 8318, Thessaloniki 57001, Greece - Tsiridis Orthopaedic Institute - ICAROS Clinic, Thessaloniki 55535, Greece.
Introduction: STAR (Superior Transverse Anatomic Reconstruction), a piriformis-preserving posterior approach, has not been extensively studied. Our study aimed to assess the STAR approach's safety and efficacy by recording postoperative complication rates and measuring implantation accuracy in a single surgeon prospective cohort with a mean follow-up of two years.
Methods: The study involved 522 patients with elective primary or complex primary total hip arthroplasty (THA) performed by a senior surgeon using the STAR approach between 2019 and 2023.
Polymers (Basel)
July 2024
Faculty of Engineering and Basic Sciences, Fundación Universitaria Los Libertadores, Bogotá 1112211, Colombia.
Biopolymers are polymers of natural origin and are environmentally friendly, carbon neutral and less energy-intense additives that can be used for various geotechnical applications. Biopolymers like xanthan gum, carrageenan, chitosan, agar, gellan gum and gelatin have shown potential for improving subgrade strength, erosion resistance, and as canal liners and in slope stabilization. But minimal research has been carried out on cellulose-based biopolymers, particularly microcrystalline cellulose (MCC), for their application in geotechnical and geo-environmental engineering.
View Article and Find Full Text PDFArthroplasty
June 2024
Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Capital Medical University, No. 31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Objective: In total knee arthroplasty (TKA), achieving soft-tissue balance while retaining acceptable lower limb alignment is sometimes difficult and may lead to patient dissatisfaction. Theoretically, patient-specific implants can bring great benefits, while the lack of precise surgical tools may hinder the improvement of outcomes. The objective of this study was to illustrate surgical techniques and evaluate kinematics and early clinical outcomes of robotic-assisted TKA using patient-specific implants.
View Article and Find Full Text PDFJ Orthop Res
September 2024
Department of Mechanical, Aerospace, and Biomedical Engineering, University of Tennessee, Knoxville, Tennessee, USA.
Hip dislocation is one of the leading causes of failure and revision surgery for total hip arthroplasty. To reduce dislocation rates, lipped liners have been designed with an elevated portion of the rim, to increase jump distance and maintain greater contact area. While it has been documented that lipped liners help reduce dislocation, the objective of this study is to investigate whether lipped liners also help reduce smaller instances of hip micromotion, separation, and edge loading.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!