Image-based characterization of powder flow to predict the success of pharmaceutical minitablet manufacturing.

Int J Pharm

Division of Pharmaceutical Chemistry and Technology, Faculty of Pharmacy, University of Helsinki, P.O. Box 56, (Viikinkaari 5E), FIN-00014, Finland.

Published: May 2020

Powder flowability plays an important role in die filling during tablet manufacturing. The present study introduces a novel small-scale measuring technique for powder flow. Based on image analysis, the flow was defined depending on the variation of luminous intensity and the movement of powder inside the measurement cuvette. Using quantities around 100 mg it was possible to characterize a wide range of common pharmaceutical powders, especially in distinguishing subtle differences in flow caused by minor changes in samples characteristics. The method was compared with powder rheometry, which is widely used in the pharmaceutical literature, and showed a significant improvement in predicting the success of pharmaceutical minitablet manufacture (d = 5 mm). Tablet weight variation (RSD) was defined as the most efficient way to assess relevant powder flow behaviour in tablet production when using the novel device. The proposed method was distinguished from others by its ability to classify different grades of microcrystalline cellulose in the die-filling process. Subsequently, eight common pharmaceutical powders, both excipients and APIs, were properly ranked as a function of flowability based on their physical properties. The method showed a high repeatability, with a relative standard deviation not more than 10%.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijpharm.2020.119280DOI Listing

Publication Analysis

Top Keywords

powder flow
12
success pharmaceutical
8
pharmaceutical minitablet
8
common pharmaceutical
8
pharmaceutical powders
8
powder
6
flow
5
pharmaceutical
5
image-based characterization
4
characterization powder
4

Similar Publications

Halogenated organic pollutants (HOPs) have attracted considerable attention owing to their persistence, bioaccumulation, and toxicity. The development of methods to detect HOPs in fish is challenging owing to the compositional complexity of fish matrices, which contain high levels of lipids and relatively low concentrations of HOPs. In addition, the lipophilicity of most HOPs renders their extraction difficult.

View Article and Find Full Text PDF

Oral administration of Bifidobacterium longum and Bifidobacterium infantis ameliorates cefcapene pivoxil-induced attenuation of anti-programmed cell death protein-1 antibody action in mice.

Biomed Pharmacother

December 2024

Department of Clinical Immuno-Oncology, Clinical Research Institute for Clinical Pharmacology and Therapeutics, Showa University, Tokyo, Japan; Division of Medical Oncology, Department of Medicine, Showa University Graduate School of Medicine, Tokyo, Japan. Electronic address:

Gut bacteria play pivotal roles in the antitumor effects of immune checkpoint inhibitors (ICIs). However, antimicrobial therapy, often necessary for infections in cancer patients, can reduce the efficacy of ICIs. The potential of probiotics to restore ICI efficacy remains uncertain.

View Article and Find Full Text PDF

Metal Pneumonitis from "Non-toxic" Decorative Cake Dust Aspiration: A Case Report.

Clin Pract Cases Emerg Med

November 2024

Atrium Health's Carolinas Medical Center, Department of Emergency Medicine, Division of Medical Toxicology, Charlotte, North Carolina.

Introduction: Metallic luster dusts are decorative agents for cakes and other confections. While some powders are labeled "non-edible," they are also marketed as "non-toxic." We present a case of a child who developed acute metal pneumonitis after accidental aspiration of metallic luster dust.

View Article and Find Full Text PDF

The aim of this study was to analyse the effect of breathing parameters, age, gender and disease status on the lung doses of the two ICS + LABA fixed combination dry powder drugs. Breathing parameters of 113 COPD patients were measured while inhaling through emptied NEXThaler® and Ellipta® inhalers and the corresponding lung doses were calculated. Lung dose of Foster® NEXThaler® was superior to the lung dose of Relvar® Ellipta® in around 85 % of the patients.

View Article and Find Full Text PDF

7 days of L-citrulline supplementation does not improve running performance in the heat whilst in a hypohydrated state.

Eur J Appl Physiol

December 2024

National Centre for Sport and Exercise Medicine, School of Sport, Exercise and Health Sciences, Loughborough University, Loughborough, UK.

Purpose: 7 days L-citrulline supplementation has been reported to improve blood pressure, O kinetics, gastrointestinal (GI) perfusion and endurance cycling performance through increasing arterial blood flow. In situations where blood volume is compromised (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!