A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Midterm Results of a Contemporary, Porous-Coated Acetabular System in Patients Undergoing Primary Total Hip Replacement for Degenerative Hip Disease: A Prospective, Multicenter Study. | LitMetric

Background: A contemporary, porous-coated acetabular implant designed for uncemented insertion was introduced in Europe and Australia in 2007. A similar previous acetabular system was found in several studies at 10 to 15-year follow-up to demonstrate accelerated polyethylene wear, osteolysis, and early failure. The current study was conducted to determine the midterm safety and effectiveness of this contemporary acetabular system using highly crosslinked polyethylene and ceramic liners at 5-year follow-up.

Methods: A prospective, nonrandomized study was conducted at 8 sites in Canada and the United States. All 148 study participants received a contemporary acetabular shell with proprietary porous coating. The primary outcome was the requirement for revision surgery at 5 years postoperatively. Secondary outcomes included a survival analysis, patient-reported outcome measures, radiographic failure, and postoperative adverse events.

Results: At 5-year follow-up there was 1 cup revised for deep infection. No cups were revised for loosening and none were found to be radiographically loose. The overall survival rate with reoperation for any reason was 97.1%. The success rate was 96.8% for polyethylene and 100% for ceramic with no difference in the success rate between either bearing surface (P = 1.0). The mean patient-reported outcome measures all improved significantly between preoperative and 5-year postoperative scores (P < .001).

Conclusion: Results from this 5-year, multicenter, prospective study indicate excellent survivorship for this acetabular system when used with crosslinked polyethylene or ceramic bearing surfaces.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2020.02.068DOI Listing

Publication Analysis

Top Keywords

acetabular system
16
contemporary porous-coated
8
porous-coated acetabular
8
study conducted
8
contemporary acetabular
8
crosslinked polyethylene
8
polyethylene ceramic
8
patient-reported outcome
8
outcome measures
8
success rate
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!