Ventilatory frequency during intraoperative mechanical ventilation and postoperative pulmonary complications: a hospital registry study.

Br J Anaesth

Department of Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA; Klinik für Anästhesiologie und Intensivmedizin, Universität Duisburg-Essen, Essen, Germany. Electronic address:

Published: July 2020

Background: High ventilatory frequencies increase static lung strain and possibly lung stress by shortening expiratory time, increasing intrathoracic pressure, and causing dynamic hyperinflation. We hypothesised that high intraoperative ventilatory frequencies were associated with postoperative respiratory complications.

Methods: In this retrospective hospital registry study, we analysed data from adult non-cardiothoracic surgical cases performed under general anaesthesia with mechanical ventilation at a single centre between 2005 and 2017. We assessed the association between intraoperative ventilatory frequency (categorised into four groups) and postoperative respiratory complications, defined as composite of invasive mechanical ventilation within 7 days after surgery or peripheral oxygen desaturation after extubation, using multivariable logistic regression. In a subgroup, we adjusted analyses for arterial blood gas parameters.

Results: A total of 102 632 cases were analysed. Intraoperative ventilatory frequencies ranged from a median (inter-quartile range [IQR]) of 8 (8-9) breaths min (Group 1) to 15 (14-18) breaths min (Group 4). High ventilatory frequencies were associated with higher odds of postoperative respiratory complications (adjusted odds ratio=1.26; 95% confidence interval, 1.14-1.38; P<0.001), which was confirmed in a subgroup after adjusting for arterial partial pressure of carbon dioxide and the ratio of arterial oxygen partial pressure to fractional inspired oxygen. We identified considerable variability in the use of high ventilatory frequencies attributable to individual provider preference (ranging from 22% to 88%) and temporal change; however, the association with postoperative respiratory complications remained unaffected.

Conclusions: High intraoperative ventilatory frequency was associated with increased risk of postoperative respiratory complications, and increased postoperative healthcare utilisation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7844371PMC
http://dx.doi.org/10.1016/j.bja.2020.02.018DOI Listing

Publication Analysis

Top Keywords

ventilatory frequencies
16
mechanical ventilation
12
intraoperative ventilatory
12
postoperative respiratory
12
ventilatory frequency
8
hospital registry
8
registry study
8
high ventilatory
8
frequencies associated
8
respiratory complications
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!