Introduction: Distal radius fractures (DRF) are the most common fractures of the upper extremities and incidence is expected to continue rising as life expectancy increases. Palmar locking plate stabilizing has since become the standard treatment for dorsally displaced DRF. Main aim of this study was to investigate correlation between radiological and clinical outcome in patients stabilized by palmar locking plate with a minimum follow-up of one year.
Methods: A total of 524 patients with DRF, stabilized using palmar angular stable locking plate fixation were included in the study. Of these, 117 patients had to be excluded and another 177 were not accessible. The study group thus compromised 230 patients who returned for the follow-up investigation and were followed-up clinically and radiologically with a mean follow-up interval of 20 months. Outcome was evaluated using pain, range of motion (ROM) and grip strength parameters. In addition, self-assessment by patients was registered on the QuickDASH, PRWE and Mayo Score. The immediate postoperative and final checkup radiographs were scrutinized for alignment and intra-articular step-off.
Results: Bivariant correlation analysis showed a significant correlation between ulnar variance and QuickDASH (r = 0.18, p = 0.01), grip strength (r = - 0.18, p = 0.04) and Mayo Score (r = - 0.23, p = 0.001). No significant differences could be found between an unacceptable (> 2 mm) and acceptable (< 2 mm) ulnar variance in respect of pain, ROM, grip strength and patient-reported outcome measurements. Age, gender, additional fracture to the ulnar styloid, or type of postoperative immobilization showed no significant or clinical important impact on the final patient-reported outcome. No significant differences in incidence of complications, ROM or loss of reduction could be found in any patients over or under 65 years of age.
Conclusions: Stabilization of DRF by palmar angular stable locking plate is a safe form of treatment and results in a good clinical and radiological outcome with low complication rate. Ulnar variance showed a significant correlation to grip strength, QuickDASH and Mayo Score, but an unacceptable ulnar variance (> 2 mm) was not associated with a worse clinical important outcome. Age (< 65/> 65 years), gender and type of immobilization had no impact on the complication rate or in the final functional or radiological outcome.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00402-020-03411-9 | DOI Listing |
Medicina (Kaunas)
January 2025
Department of Orthopedic Surgery, Anam Hospital, Korea University College of Medicine, 73 Goryeodae-ro Seongbuk-gu, Seoul 02841, Republic of Korea.
Distal tibia fractures are high-energy injuries characterized by a mismatch between standard plate designs and the patient's specific anatomical bone structure, which can lead to severe soft tissue damage. Recent advancements have focused on the development of customized metal plates using three-dimensional (3D) printing technology. However, 3D-printed metal plates using titanium alloys have not incorporated a locking system due to the brittleness of these alloys.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedics and Traumatology, Karabük University, Karabük 78050, Turkey.
The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.
View Article and Find Full Text PDFEur J Trauma Emerg Surg
January 2025
Bowen University Teaching Hospital, P. O. Box 15, Ogbomoso, Oyo State, Nigeria.
Purpose: To investigate the factors that prolonged the operative duration (OD) in patients who underwent single-stage locked intramedullary nailing of their multiple concurrent long-bone fractures (LBFs) using Surgical Implant Generation Network (SIGN) nails.
Methods: Forty-nine patients who fulfilled the inclusion criteria were enrolled prospectively over 8½ years. Data collected included age, sex, injury mechanism and severity, fracture characteristics, nail types and diameter, OD, fracture-to-fixation time, length of hospital stay (LOS), functional outcomes and complications.
Arch Orthop Trauma Surg
January 2025
Department of Orthopaedics, Wright State University, 30 E Apple St., Suite 2200, Dayton, OH, 45409, USA.
Introduction: We propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.
Materials And Methods: Twenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!