Introduction: There are many craniometric measurements that are used in evaluating craniovertebral junction (CVJ) pathologies such as basilar invagination, atlantoaxial dislocation and platybasia. Therefore, it is important to determine the normal reference range of the craniometric measurements. This study aims to determine the morphometric reference values of the bony structures in the CVJ from cone-beam computed tomography (CBCT) images of a group of South Eastern Anatolian population.
Materials And Methods: The CBCT images of 300 individuals were retrospectively evaluated. 14 parameters on midsagittal and 2 parameters on the coronal plane were studied. The data were statistically evaluated.
Results: Measurement results were found as follows; the distances between odontoid process (OP) and McGregor line as 0.31 ± 3.22 mm, OP and Chamberlain line 1.06 ± 3.22 mm, OP and McRae line 5.30 ± 1.59 mm, OP and Fischgold digastric line 8.70 ± 4.12 mm, OP and Fischgold bimastoid line - 5.15 ± 4.86 mm, length of McRae line 35.58 ± 2.52 mm, atlantodental interval 1.28 ± 0.48 mm, posterior atlantodental interval 19.54 ± 2.24 mm, basion axial interval 4.01 ± 1.83 mm, basion dental interval 4.92 ± 1.77 mm, length of Modified Ranawat line 28.66 ± 2.38 mm, length of Redlund-Johnell line 35.11 ± 4.09 mm, clivus canal angle 157.62° ± 11.85°, Welcher basal angle 130.83° ± 6.29°, craniocervical tilt 126.98° ± 12.24° and Powers ratio as 0.72 ± 0.06.
Conclusion: In this study, the morphometric values were evaluated according to age and gender in individuals who did not have any radiologic anomalies. The normal reference ranges may be useful for researchers who are researching pathology in this region. It is recommended to conduct further studies with different populations to determine the normal reference range.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00276-020-02457-z | DOI Listing |
Herzschrittmacherther Elektrophysiol
January 2025
Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Carl-Neuberg Str. 1, 30625, Hannover, Germany.
Background: The QRS axis of the electrocardiogram (ECG) is often considered in clinical practice, but its determination is frequently limited to a rough estimation, such as "normal", with left or right deviation, and superior or inferior in the case of premature ventricular complexes (PVCs). However, a more exact determination of the QRS axis may be warranted in certain scenarios, such as to determine the origin of PVCs more precisely, and is attainable by visual estimation using the hexaxial reference system.
Objectives: The aim of this study was to determine how well such an estimation of the QRS axis would correlate with the axis calculated by formulas.
Sci Rep
January 2025
School of Chemical Engineering, Sichuan University, Chengdu, 610065, China.
The magnetization strategy of isoquinoline alkaloids has been successfully used in the extraction and isolation, but the effect of the magnetization on biological activities of those alkaloids still deserves further investigation. Therefore, the antibacterial, lipid-lowering and antioxidant activities of five isoquinoline alkaloids (berberine, tetrahydroberberine, palmatine, tetrahydropalmatine and tetrahydropapavine) before and after magnetization were compared in this study, and the results showed that the relevant activities were enhanced after magnetization. Additionally, among the five magnetic derivatives studied, berberine magnetic derivative ([Ber·H][FeCl]) had the best antibacterial effect on S.
View Article and Find Full Text PDFEur J Clin Nutr
January 2025
Professor Emeritus, Department of Kinesiology and Health Education, University of Texas, Austin, TX, USA.
Background/objective: To evaluate the weight and height status of under-five children between 1992 and 2021 in relation to nutritional context.
Subjects/methods: The study is based on the lengths/heights and weights of children <5 years in five national surveys (n = 505,026). After evaluating normality of the distributions, heights, and weights were expressed as z-scores relative to the WHO reference.
Sci Rep
January 2025
Department of Endocrinology, Beijing Tongren Hospital, Capital Medical University, No.2, Xihuan South Road, Beijing Economic and Technological Development Zone, Daxing District, Beijing, China.
Spirometry findings, such as restrictive spirometry and airflow obstruction, are associated with renal outcomes. Effects of spirometry findings such as preserved ratio impaired spirometry (PRISm) and its trajectories on renal outcomes are unclear. This study aimed to investigate the impact of baseline and trajectories of spirometry findings on future chronic kidney disease (CKD) events.
View Article and Find Full Text PDFVox Sang
January 2025
Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, Stockholm, Sweden.
Background And Objectives: Access to blood components in pre-hospital bleeding resuscitation is challenging. Dried plasma is a logistically superior alternative, and new products are emerging. Therefore, we aimed to evaluate laboratory and practical differences in three differently produced dried plasma products.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!