A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Alveolar Bone Density and Width Affect Primary Implant Stability. | LitMetric

Primary implant stability (PIS) depends on surgical technique, implant design, and recipient bone characteristics, among other factors. Bone density (BD) can be determined in Hounsfield units (HUs) using cone beam computerized tomography (CBCT). Reliable prediction of PIS could guide treatment decisions. We assessed whether PIS was associated with recipient bone characteristics, namely, BD and alveolar ridge width (ARW), measured preoperatively by CBCT. We studied a convenience sample of 160 implants placed in 48 patients in 2016 and 2017. All underwent CBCT with a radiologic/surgical guide yielding values for ARW and BD. PIS measures used were the implant stability quotient (ISQ) from resonance frequency analysis and insertion torque (IT). IT was most influenced by the HU value at 0.5 mm outside the implant placement area, followed by the value within this area, and ISQ by the HU value at 0.5 mm outside the placement area, followed by implant placement site and apical ARW. ISQ values were significantly related to ARW in coronal (P < .05), middle (P < .01), and apical (P < .01) thirds. ISQs were higher with larger-diameter implants (P < .01). ISQ and IT were strongly correlated (P < .001). PIS in terms of ISQ and IT is positively correlated with edentulous alveolar ridge BD measured by CBCT, implying that implant stability may be predicted preoperatively. Wide alveolar ridges favored lateral PIS but did not affect rotational PIS. The most significant predictor of lateral and rotational PIS in our patients was the HU value at 0.5 mm outside the implant placement area.

Download full-text PDF

Source
http://dx.doi.org/10.1563/aaid-joi-D-19-00028DOI Listing

Publication Analysis

Top Keywords

implant stability
16
implant placement
12
placement area
12
bone density
8
implant
8
primary implant
8
pis
8
recipient bone
8
bone characteristics
8
alveolar ridge
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!