A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biodegradation ZK50 magnesium alloy compression screws: Mechanical properties, biodegradable characteristics and implant test. | LitMetric

Background: Magnesium alloy implants have lower stress load and can be absorbed gradually, but their degradation rates are too fast generally. A magnesium alloy contained 5% Zn and 0.5% Zr (ZK50) which have lower degradation rate are designed to be applied to cannulated bone screw.

Methods: An oxidation heat treatment of 380 °C for 2 h proceeds to modify the ZK50 Mg alloy (ZK50-H). The microstructure observation, degradation tests and Biocompatibility analysis are proceeded between ZK50 and ZK50-H. Finally, a mini-pig implantation test is proceeded to provide a reference of implant application for future pre-clinical evaluation.

Results: The heat treatment can improve the mechanical properties. A passive ceramic layer formed after simulated body fluid (SBF) solution immersion can restrict the degradation effectively. The cytotoxicity test shows the initial biosafety of ZK50 Mg alloy. A mini-pig implantation test of bone screw has proceeded to confirm the advanced biocompatibility. The ZK50-H screws can maintain enough support at least 8 weeks which the fracture of bone can get curing. The excellent osteoinduction of ZK50-H has a positive effect to growth of new bones and help the mini-pig regain heal faster in 12 weeks.

Conclusion: This study shows ZK50-H Mg alloy screw is a feasible degradation implant and can be carried out the next-step clinical experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jos.2020.01.018DOI Listing

Publication Analysis

Top Keywords

magnesium alloy
12
mechanical properties
8
heat treatment
8
zk50 alloy
8
mini-pig implantation
8
implantation test
8
alloy
6
degradation
5
zk50-h
5
biodegradation zk50
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!