A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultra-Sensitive Minute Mass Sensing Using a Microcantilever Virtually Coupled with a Virtual Cantilever. | LitMetric

Mass sensors based on the eigenmode shift of coupled cantilevers achieve much higher sensitivity than those based on the single cantilever's eigenfrequency shift. In the former sensors, two identical cantilevers and a weak coupling stiffness between them are required to achieve high sensitivity. However, conventional coupled cantilevers cannot satisfy these requirements because of machining accuracy. To satisfy both requirements, a virtual coupling between a real macrocantilever and a virtual cantilever, whose dynamics was calculated using a digital computer, was proposed in our previous research. The sensitive mass sensing of mg-order masses was achieved. In the present work, for minute mass sensing, we replace the real macrocantilever with a real microcantilever. The calculation speed of a digital computer is not fast enough to calculate the virtual cantilever's dynamics because the natural frequency of the microcantilver is much higher than that of the macrocantilever. Therefore, we use an analog circuit instead of a digital computer to achieve virtual coupling with the virtual cantilever. The proposed system enables us to tune the virtual cantilever's parameters to satisfy both requirements for high sensitivity by changing the analog circuit parameters. We verified experimentally that the proposed system achieved high sensitivity for mass sensing of the order of nanograms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7180872PMC
http://dx.doi.org/10.3390/s20071823DOI Listing

Publication Analysis

Top Keywords

mass sensing
16
virtual cantilever
12
high sensitivity
12
satisfy requirements
12
digital computer
12
minute mass
8
coupled cantilevers
8
virtual coupling
8
real macrocantilever
8
virtual cantilever's
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!