A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Design, Implementation, and Validation of a Pediatric ICU Sepsis Prediction Tool as Clinical Decision Support. | LitMetric

Background: Sepsis is an uncontrolled inflammatory reaction caused by infection. Clinicians in the pediatric intensive care unit (PICU) developed a paper-based tool to identify patients at risk of sepsis. To improve the utilization of the tool, the PICU team integrated the paper-based tool as a real-time clinical decision support (CDS) intervention in the electronic health record (EHR).

Objective: This study aimed to improve identification of PICU patients with sepsis through an automated EHR-based CDS intervention.

Methods: A prospective cohort study of all patients admitted to the PICU from May 2017 to May 2019. A CDS intervention was implemented in May 2018. The CDS intervention screened patients for nonspecific sepsis criteria, temperature dysregulation and a blood culture within 6 hours. Following the screening, an interruptive alert prompted nursing staff to complete a perfusion screen to assess for clinical signs of sepsis. The primary alert performance outcomes included sensitivity, specificity, and positive and negative predictive value. The secondary clinical outcome was completion of sepsis management tasks.

Results: During the 1-year post implementation period, there were 45.0 sepsis events per 1,000 patient days over 10,805 patient days. The sepsis alert identified 392 of the 436 sepsis episodes accurately with sensitivity of 92.5%, specificity of 95.6%, positive predictive value of 46.0%, and negative predictive value of 99.7%. Examining only patients with severe sepsis confirmed by chart review, test characteristics fell to a sensitivity of 73.3%, a specificity of 92.5%. Prior to the initiation of the alert, 18.6% (13/70) of severe sepsis patients received recommended sepsis interventions. Following the implementation, 34% (27/80) received these interventions in the time recommended,  = 0.04.

Conclusion: An EHR CDS intervention demonstrated strong performance characteristics and improved completion of recommended sepsis interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7096320PMC
http://dx.doi.org/10.1055/s-0040-1705107DOI Listing

Publication Analysis

Top Keywords

cds intervention
16
sepsis
14
clinical decision
8
decision support
8
paper-based tool
8
negative predictive
8
patient days
8
severe sepsis
8
recommended sepsis
8
sepsis interventions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!