Importance: Evaluating corneal morphologic characteristics with corneal tomographic scans before refractive surgery is necessary to exclude patients with at-risk corneas and keratoconus. In previous studies, researchers performed screening with machine learning methods based on specific corneal parameters. To date, a deep learning algorithm has not been used in combination with corneal tomographic scans.

Objective: To examine the use of a deep learning model in the screening of candidates for refractive surgery.

Design, Setting, And Participants: A diagnostic, cross-sectional study was conducted at the Zhongshan Ophthalmic Center, Guangzhou, China, with examination dates extending from July 18, 2016, to March 29, 2019. The investigation was performed from July 2, 2018, to June 28, 2019. Participants included 1385 patients; 6465 corneal tomographic images were used to generate the artificial intelligence (AI) model. The Pentacam HR system was used for data collection.

Interventions: The deidentified images were analyzed by ophthalmologists and the AI model.

Main Outcomes And Measures: The performance of the AI classification system.

Results: A classification system centered on the AI model Pentacam InceptionResNetV2 Screening System (PIRSS) was developed for screening potential candidates for refractive surgery. The model achieved an overall detection accuracy of 94.7% (95% CI, 93.3%-95.8%) on the validation data set. Moreover, on the independent test data set, the PIRSS model achieved an overall detection accuracy of 95% (95% CI, 88.8%-97.8%), which was comparable with that of senior ophthalmologists who are refractive surgeons (92.8%; 95% CI, 91.2%-94.4%) (P = .72). In distinguishing corneas with contraindications for refractive surgery, the PIRSS model performed better than the classifiers (95% vs 81%; P < .001) in the Pentacam HR system on an Asian patient database.

Conclusions And Relevance: PIRSS appears to be useful in classifying images to provide corneal information and preliminarily identify at-risk corneas. PIRSS may provide guidance to refractive surgeons in screening candidates for refractive surgery as well as for generalized clinical application for Asian patients, but its use needs to be confirmed in other populations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7099445PMC
http://dx.doi.org/10.1001/jamaophthalmol.2020.0507DOI Listing

Publication Analysis

Top Keywords

refractive surgery
16
candidates refractive
12
deep learning
12
corneal tomographic
12
screening candidates
8
model pentacam
8
model achieved
8
achieved detection
8
detection accuracy
8
data set
8

Similar Publications

Purpose: To investigate changes in eye alignment before and after ICL implantation in patients with myopia having corrected distance visual acuity (CDVA) of ≥0.0 logMAR.

Subjects And Methods: The medical records of 1012 patients without eye movement limitation who underwent bilateral ICL implantation were retrospectively reviewed a at the Eye Center of Sanno Hospital in Japan.

View Article and Find Full Text PDF

SMILE for correction of myopia in patients during the incipient phase of presbyopia.

Int Ophthalmol

January 2025

Department of Ophthalmology, Peking University Third Hospital, No 49 Huayuan North Road, Haidian District, Beijing, 100191, China.

Purpose: To evaluate clinical outcomes and visual quality 12 months after small incision lenticule extraction (SMILE) for correction of myopia with or without astigmatism in patients during the incipient phase of presbyopia.

Setting: Peking University Third Hospital, Beijing, China.

Design: Retrospective observation study.

View Article and Find Full Text PDF

Purpose: To assess the effect of anterior chamber depth on corneal endothelium using specular microscopy following uneventful phacoemulsification among cataract patients with different axial lengths.

Methods: The study was conducted in a quasi-experimental design including 300 eyes of 300 patients with grade three age-related nuclear cataract distributed equally based on their axial length into three equal groups. All eyes had grade three nuclear cataract.

View Article and Find Full Text PDF

Peribulbar anesthesia is mainly used for cataract surgery. Many studies had used atracurium and rocuronium as an additive to the local anesthetic (LA) drugs in eye surgery. The aim of this study is to evaluate the efficacy of adding atracurium versus rocuronium to a local anesthetic mixture, in providing an early onset of orbital akinesia and corneal anesthesia during cataract surgery.

View Article and Find Full Text PDF

Background/aims: To identify the risk factors for neuropathic corneal pain (NCP) following corneal refractive surgery and to report its clinical manifestations, imaging and proteomic characteristics.

Methods: This 1 year prospective cohort study included 100 eyes that underwent small incision lenticule extraction (SMILE) or laser-assisted in situ keratomileusis (LASIK). Ocular surface assessments, in-vivo confocal microscopy scans, tear neuromediators and proteomics analyses were performed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!