Infrared thermography (IRT), as a noncontact tool for temperature measurement, is widely applied in the study of acupuncture modernization. The aim of this study was to assess the intra- and interrater reliability of infrared image analysis of facial acupoints of subjects with facial paralysis and determine the factors influencing the variability of the measured values. A total of 26 patients with facial paralysis on one side, aged 26 to 53 years, participated voluntarily in the study. Facial infrared thermal images of all participants were analyzed by two trained raters at two different time points at a one-week interval. The intraclass correlation coefficient (ICC) was used to determine the intra- and interrater reliability of IRT measurements. The ICC values varied depending on the analyzed acupoints. The reliability of temperature measurement ranged from moderate to excellent (intrarater, ICC ranged from 0.669 to 0.990; interrater, ICC ranged from 0.661 to 0.987). The reliability of temperature difference measurement ranged from low to excellent (intrarater, ICC ranged from 0.412 to 0.882; interrater, ICC ranged from 0.334 to 0.828). The main influencing factor of reliability is the incomplete consistency in selecting acupoint positions when repeatedly positioning the same acupoint manually. Despite low reliability of temperature difference measurement at some acupoints, some auxiliary measures can be used to reduce the error of manual positioning. Thus, infrared thermal imaging still has the potential to assist in objective and quantitative research on acupuncture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7077041PMC
http://dx.doi.org/10.1155/2020/9079037DOI Listing

Publication Analysis

Top Keywords

icc ranged
16
intra- interrater
12
interrater reliability
12
facial paralysis
12
reliability temperature
12
reliability infrared
8
infrared image
8
image analysis
8
analysis facial
8
facial acupoints
8

Similar Publications

Unlabelled: In recent years, the EnodePro device has been one of the most frequently used velocity sensors to track the bar velocity in resistance training, with the aim of providing load-velocity profiles. However, recent articles highlight a lack of reliability and validity in the estimated maximal strength, which can cause a serious health risk due to the overestimation of the bar velocity. With this study, we aimed to investigate whether imprecision in the measurement could explain the variance in this measurement error.

View Article and Find Full Text PDF

This study aimed to assess the intraday reliability of markerless gait analysis using an RGB-D camera versus a traditional three-dimensional motion analysis (3DMA) system with and without a simulated walking assistant. Gait assessments were conducted on 20 healthy adults walking on a treadmill with a focus on spatiotemporal parameters gathered using the RGB-D camera and 3DMA system. The intraday reliability of the RGB-D camera was evaluated using intraclass correlation coefficients (ICC 1, 1), while its consistency with the 3DMA system was determined using ICC (2, 1).

View Article and Find Full Text PDF

Motor Assessment Timed Test (MATT): A New Timed Test to Assess Functional Mobility in Parkinson's Disease Patients.

J Clin Med

January 2025

Health, Physical Activity and Sports Technology (HEALTH-TECH), Department of General and Specific Didactics, Faculty of Education, University of Alicante, 03690 Alicante, Spain.

: Parkinson's disease (PD) is a neurodegenerative disorder that significantly impairs motor function, leading to mobility challenges and an increased risk of falls. Current assessment tools often inadequately measure the complexities of motor impairments associated with PD, highlighting the need for a reliable tool. This study introduces the Motor Assessment Timed Test (MATT), designed to assess functional mobility in PD patients.

View Article and Find Full Text PDF

This study evaluated the validity and reliability of the TecnoBody D-Wall system in assessing joint range of motion (ROM) during overhead squat movements in healthy individuals, using Kinovea as a reference tool for data comparison. A total of 29 participants (16 males, 13 females) with a mean age of 28.41 ± 6.

View Article and Find Full Text PDF

: Measuring joint range of motion (ROM) is essential for diagnosing and treating musculoskeletal diseases. However, most clinical measurements are conducted using conventional devices, and their reliability may significantly depend on the tester. This study implemented an RGB-D (red/green/blue-depth) sensor-based artificial intelligence (AI) device to measure joint ROM and compared its reliability with that of a universal goniometer (UG).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!