Background: Bioresorbable vascular scaffolds (BVS) are promising alternatives to metallic drug-eluting stents (DES) in percutaneous coronary interventions. Absorb BVS was comparable to XIENCE (DES) for patient- and device-oriented composite endpoints through 1 year post-procedure. Mid-term results showed increased rates of device-oriented events with Absorb. The objective of this study was to evaluate the long-term safety and effectiveness of Absorb BVS compared with XIENCE metallic DES when implanted in patients in Japan with de novo coronary artery lesions.

Methods and results: ABSORB Japan randomized 400 patients into either Absorb (n=266) or XIENCE (n=134) treatment arm. Through 5-year follow-up, the composite endpoints of DMR (death, myocardial infarction [MI], and all revascularization), target vessel failure (TVF), major adverse cardiac events (MACE), target lesion failure (TLF), and cardiac death/all MI were evaluated. Individual endpoints included death, MI, coronary revascularization, and scaffold/stent thrombosis. There were no significant differences in the composite or individual endpoint outcomes between the Absorb and XIENCE arms through 5 years or between 3 and 5 years. Numerically lower TVF, MACE, and all MI rates were observed for the Absorb vs. XIENCE arm after 3 years. No scaffold/stent thrombosis was reported beyond 3 years. Post-procedure imaging subgroups showed comparable event rates.

Conclusions: Following resorption of the scaffold, between 3 and 5 years post-procedure, the Absorb BVS performed comparably to XIENCE in all patient- and device-oriented endpoints (ClinicalTrials.gov, #NCT01844284).

Download full-text PDF

Source
http://dx.doi.org/10.1253/circj.CJ-19-1184DOI Listing

Publication Analysis

Top Keywords

absorb bvs
12
absorb
9
outcomes absorb
8
bioresorbable vascular
8
patient- device-oriented
8
composite endpoints
8
scaffold/stent thrombosis
8
absorb xience
8
years post-procedure
8
years
6

Similar Publications

Background: The risk-benefit ratio of the Absorb bioresorbable vascular scaffold (BVS) may vary before and after 3 years, the time point of complete bioresorption of the poly-L-lactic acid scaffold.

Objectives: The aim of this study was to determine the time-varying outcomes of the Absorb BVS compared with cobalt-chromium everolimus-eluting stents (EES) from a large individual-patient-data pooled analysis of randomized trials.

Methods: The individual patient data from 5 trials that randomized 5,988 patients undergoing percutaneous coronary intervention to the Absorb BVS vs EES with 5-year follow-up were pooled.

View Article and Find Full Text PDF

Crystal structure and morphology dictate the mechanical, thermal, and degradation properties of poly l-lactide (PLLA), the structural polymer of the first clinically approved bioresorbable vascular scaffolds (BVS). New experimental methods are developed to reveal the underlying mechanisms governing structure formation during the crimping step of the BVS manufacturing process. Our research specifically examines the "U-bends" - the region where the curvature is highest and stress is maximised during crimping, which can potentially lead to failure of the device with dramatic consequences on patient life.

View Article and Find Full Text PDF

Background: Data on Absorb bioresorbable vascular scaffold (BVS) use in patients presenting with ST-segment elevation myocardial infarction (STEMI) are limited. Furthermore, Absorb studies including STEMI patients lacked a prespecified implantation technique to optimize BVS deployment. This study examines the 5-year outcomes of BVS in STEMI patients using an optimized implantation strategy and the impact of prolonged dual antiplatelet therapy (DAPT).

View Article and Find Full Text PDF

Background: In patients with in-stent restenosis (ISR) bioresorbable vascular scaffolds (BVS) provide similar results to drug-coated balloons (DCBs) but are inferior to drug-eluting stents (DES) at 1 year. However, the long-term efficacy of BVS in these patients remains unknown.

Objectives: This study sought to assess the long-term safety and efficacy of BVS in patients with ISR.

View Article and Find Full Text PDF

This review aimed to explore the therapeutic effect of bioabsorbable stents in the inferior genicular artery, from the emergence of absorbable bare metal stents to the latest technology in polymer and anti-proliferative eluting drugs mixed with coated bioresorbable vascular stents (BVSs). Currently, there are conflicting data regarding the safety and effectiveness of BVSs in infrapopliteal artery interventions, especially compared to the current generation of drug-eluting stents (DESs). This review will cover the existing data on BVSs in reconstructing the infrapopliteal arterial blood flow and active clinical trials for future iterations of BVSs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!