Aim: To explore the feasibility and value of transthoracic echocardiography (TTE) postprocessing subtraction technique in the detection of a stent in the coronary artery.

Method: Transthoracic echocardiography was used to examine 46 coronary artery stents in 30 patients by two-dimensional ultrasound postprocessing subtraction technique. The shape of each stent and its flow patency were observed. The patency was assessed according to blood flow and mosaic flow in the stent. Then, the results were compared with those of percutaneous coronary intervention (PCI) records and coronary angiography (CAG).

Results: Transthoracic echocardiography detected 36 stents among 46 stents (two in the LMCA, 23 in the LAD, seven in the RCA, and two in the LCX); the detection rate was 78.3%. The average length of the stents was 21.8 ± 4.1 mm, and the average diameter was 2.4 ± 0.5 mm; both are shorter than those from PCI records (P < .001). Of the 36 stents, blood flow could be observed in 27. Compared with the results of CAG, TTE had 75% feasibility and 92.6% accuracy in detecting flow patency in the stents.

Conclusion: Transthoracic echocardiography postprocessing subtraction technique could be a noninvasive method for detecting a coronary artery stent and, although the measurements of stent length and diameter were shorter than those of PCI records, an accurate detection of flow patency in the stents was achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1111/echo.14644DOI Listing

Publication Analysis

Top Keywords

transthoracic echocardiography
16
postprocessing subtraction
12
subtraction technique
12
coronary artery
8
artery stents
8
pci records
8
coronary
5
stents
5
noninvasive detection
4
detection coronary
4

Similar Publications

Fluid administration is widely used to treat hypotension in patients undergoing veno-venous extracorporeal membrane oxygenation (VV-ECMO). However, excessive fluid administration may lead to fluid overload can aggravate acute respiratory distress syndrome (ARDS) and increase patient mortality, predicting fluid responsiveness is of great significance for VV-ECMO patients. This prospective single-center study was conducted in a medical intensive care unit (ICU) and finally included 51 VV-ECMO patients with ARDS in the prone position (PP).

View Article and Find Full Text PDF

Aims: This study compared echocardiography (echo) and cardiac computed tomography (CT) in measuring the Wilkins score and evaluated the potential added benefit of CT in predicting immediate percutaneous mitral valvuloplasty (PMV) outcomes in rheumatic mitral stenosis (MS) patients deemed eligible for PMV by echo.

Methods And Results: From a multicentre registry of 3,140 patients with at least moderate MS, we included 96 patients (age 56.4±11.

View Article and Find Full Text PDF

We present a case of a 72-year-old female patient with dyspnea and lipothymia. Echocardiography demonstrates an intracavitary cystic mass that fills almost all left atria causing supravalvular obstruction. The magnetic resonance image revealed a 53 × 47 × 48 mm heterogeneous mass with regular edges, tissue characterization suggested myxoma.

View Article and Find Full Text PDF

A 43-year-old woman presented with dyspnea and cough, initially misdiagnosed as respiratory syncytial virus. Persistent symptoms led to pulmonary thromboembolism treatment, but worsening issues revealed recurrent pericardial effusion. Imaging and biopsy confirmed pulmonary artery intimal sarcoma, mimicking thromboembolism, and autoimmune disease, underscoring diagnostic challenges.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!