A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Portable compression devices in total joint arthroplasty: poor outpatient compliance. | LitMetric

Background: Aspirin and mechanical compression devices are approved means of venous thromboembolism (VTE) prophylaxis after total joint arthroplasty. Prior studies of mechanical compression pumps after joint arthroplasty have been limited to the inpatient setting. The purpose of this study was to evaluate outpatient compliance and utilization factors in a rural population after elective hip or knee arthroplasty.

Methods: Utilization for portable pneumatic compression pumps after joint arthroplasty was prospectively recorded (hours). Compliance was defined as the recommended 20 hours per day. A questionnaire 2 weeks postoperatively assessed factors that may contribute to noncompliance. Patients were followed up for 90 days postoperatively to record VTE events.

Results: Data were collected for 115 joint arthroplasty patients (50 hips, 65 knees). Postdischarge day one had the highest average usage at 13.2 hours/day (66.0%, range 0%-100%), but this number fell to 4.8 hours/day (24.0, range 0%-100%) by day 14. Patient compliance (>20 hours use/day) was highest on postdischarge day one at 40 patients (34.7%). By postdischarge day 14, patient compliance fell to 17 patients (14.8%). Difficulty using the pumps ( = .027) and pump-associated heat ( = .009) were significantly associated with patient compliance. A deep vein thrombosis and nonfatal pulmonary embolism were recorded in 2 separate patients.

Conclusions: This study demonstrated poor outpatient compliance with portable pneumatic compression devices. Poor compliance was related to pump heat and difficulty with pump use. Even with poor compliance, a low incidence of VTE events was observed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7083727PMC
http://dx.doi.org/10.1016/j.artd.2019.12.004DOI Listing

Publication Analysis

Top Keywords

joint arthroplasty
20
compression devices
12
outpatient compliance
12
postdischarge day
12
patient compliance
12
compliance
9
total joint
8
poor outpatient
8
mechanical compression
8
compression pumps
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!