Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Mitral valve prolapse (MVP) is the most common anomaly of the mitral valve. Several studies have shown prevalence of MVP in atrial septal defect (ASD) especially secundum types (II). The aims of this study is to show the potential role of 3D echocardiography in improving the diagnosis of MVP and to depict the relationship between reverse remodeling of the right and left ventricles (RV, LV) and MVP after transcatheter closure of ASD II. Sixty patients underwent transcatheter closure of ASD II and completed follow up by 2D and 3D echocardiography in Cairo University Children Hospital before the procedure and at 24 hours, 1 and 6 months after the procedure. 3D echocardiography was more accurate than 2D echocardiography in detecting MVP frequency in ASD II patients (75% vs. 50%). Maximum statistically significant remodeling was detected by 3D echocardiography 1 month after the procedure (RV: LV ratio by 3D echocardiography 1.9±0.03 24 hours after the procedure vs. 1.6±0.03 1 months after the procedure, <0.01) while 2D echocardiography was delayed in detecting biventricular reverse remodeling. 3D derived RV: LV ratio was accurate in detecting MVP status with a sensitivity of 88%. MVP in ASD II may be related to Biventricular remodeling; 3D echocardiography is accurate in the detection of reverse remodeling as well as MVP in ASD II patients before and after device closure.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7080331 | PMC |
http://dx.doi.org/10.34172/jcvtr.2020.03 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!