Deep-seated epileptic focus estimation using magnetoencephalography is challenging because of its low signal-to-noise ratio and the ambiguity of current sources estimated by interictal epileptiform discharge (IED). We developed a distributed source (DS) analysis method using a volume head model as the source space of the forward model and standardized low-resolution brain electromagnetic tomography combined with statistical methods (permutation tests between IEDs and baselines and false discovery rate between voxels to reduce variation). We aimed to evaluate the efficacy of the combined DS (cDS) analysis in surgical cases. In total, 19 surgical cases with adult and pediatric focal epilepsy were evaluated. Both cDS and equivalent current dipole (ECD) analyses were performed in all cases. The concordance rates of the two methods with surgically identified epileptic foci were calculated and compared with surgical outcomes. Concordance rates from the cDS analysis were significantly higher than those from the ECD analysis (68.4% vs. 26.3%), especially in cases with deep-seated lesions, such as in the interhemispheric, fronto-temporal base, and mesial temporal structures (81.8% vs. 9.1%). Furthermore, the concordance rate correlated well with surgical outcomes. In conclusion, cDS analysis has better diagnostic performance in focal epilepsy, especially with deep-seated epileptic focus, and potentially leads to good surgical outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093400PMC
http://dx.doi.org/10.1038/s41598-020-62098-5DOI Listing

Publication Analysis

Top Keywords

cds analysis
12
surgical outcomes
12
distributed source
8
source analysis
8
volume head
8
head model
8
combined statistical
8
statistical methods
8
deep-seated epileptic
8
epileptic focus
8

Similar Publications

A sensitized dual-response ratiometric fluorescent sensor integrated smartphone platform for accurate discrimination and detection of tetracycline homologues based on N-CDs‒Eu complex.

Mikrochim Acta

January 2025

Key Laboratory of Environmental Remediation and Ecological Health, Ministry of Education, College of Environmental and Resource Sciences, Zhejiang University, Hangzhou, 310058, China.

A sensitized dual-response ratiometric fluorescent sensor integrated smartphone platform for accurate discrimination and detection of tetracycline (TC) homologues was fabricated based on N-CDs-Eu complex. In the sensing system, N-CDs act as a sensitizer of Eu and significantly enhance the fluorescence of TC-Eu complex approximate 40-fold owing to the synergistic effect of antenna effect (AE) and fluorescence resonance energy transfer (FRET). A paper sensor integrated with a smartphone platform is further fabricated for on-site measurement of TC.

View Article and Find Full Text PDF

In this study, we present an intelligent electromagnetic-actuated microfluidic chip integrated with a G-quadruplex DNAzyme-based biocatalysis platform for rapid and sensitive tetracycline (TC) detection. In this sensing system, TC significantly quenches fluorescent magnetic carbon dots (M-CDs) via the internal filtration effect and dynamic quenching (the excitation and emission wavelength at 350 and 440 nm, respectively). Then, the G-quadruplex on the M-CDs-Aptamer is exposed and bound with hemin to form hemin-G-quadruplex DNAzyme, catalyzing the conversion of 3,3',5,5'-tetramethylbenzidine to produce blue color.

View Article and Find Full Text PDF

Mercury ions (Hg) seriously harm the central nervous system of humans, leading to brain damage and even heart failure and death. Therefore, effective detection of Hg in water quality has become an urgent research field. It is very important to develop economically efficient fluorescent sensors to achieve rapid and sensitive detection of Hg.

View Article and Find Full Text PDF

High quantum yield copper nanoclusters integrated with nitrogen-doped carbon dots for off-on ratiometric fluorescence sensing of S and Zn.

Talanta

January 2025

Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan, 430074, PR China.

Pursuing nanomaterials with high fluorescence quantum yields is of great significance in the fields of bioimaging, medical diagnosis, and food safety monitoring. This work reports on orange-emitting aggregation-induced emission (AIE) copper nanoclusters (Cu NCs) integrated with blue-emitting nitrogen-doped carbon dots (N-CDs), which enables highly sensitive detection of S and Zn ions through an off-on ratiometric fluorescence method. The highly emissive Cu NCs was doped by Ce with a high quantum yield of 51.

View Article and Find Full Text PDF
Article Synopsis
  • The introduction describes the growing issue of postoperative complications and how a new risk stratification tool, CARES-ML, aims to reduce these risks by identifying high-risk patients early.
  • The study design involves a randomized controlled trial with over 9,200 patients undergoing elective surgeries, comparing outcomes between those guided by the CARES tool and those who are not.
  • The ethics section ensures patient consent and language support, with the study approved by the relevant review board and funding from Singapore’s National Medical Research Council, leading to findings that will be shared in peer-reviewed journals.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!