Removal of hexavalent chromium [Cr(VI)] from soils and water has been widely studied for its high toxicity. Although leaching method is viewed as an effective approach to eliminate Cr(VI) and some studies attempted to enhance leaching performance via the external electric field, there is little knowledge about the influential factor in electro-leaching system on Cr(VI) removal performance. In this study, an electro-leaching technology was developed for removing Cr(VI) from groundwater aquifer to comprehensively discuss the correlation between the operational parameters and Cr(VI) removal efficiency. When the applied voltage was 20 V and the initial Cr(VI) concentration was 40 mg/kg, Cr(VI) removal efficiency achieved 99.9% in 120 min in the electro-leaching system, 15% higher than the system without the electric field. Cr(VI) removal efficiencies increased with the voltage demonstrating the significant enhancement of the electro-leaching method in removing Cr(VI). When Cr(VI) concentration climbed to 120 mg/kg, Cr(VI) removal efficiency remained above 85%. The effects of different voltages, Cr(VI) concentrations, pollutant distribution and salt content of leaching solution on the leaching effect were also investigated. Meanwhile, the relationship between the current intensity change and the amount of removed Cr(VI) during the electro-leaching process was first investigated, and the relevant model was fitted. There is a quadratic linear correlation between the amount of current change and the amount of removed Cr(VI). This novel electro-enhanced leaching method can effectively remove Cr(VI) from contaminated groundwater aquifer by enhancing the migration of charged contaminant ions during the leaching process, and it is worthy of further study of heavy metal remediation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7093520PMC
http://dx.doi.org/10.1038/s41598-020-60896-5DOI Listing

Publication Analysis

Top Keywords

crvi removal
20
crvi
15
leaching method
12
groundwater aquifer
12
removal efficiency
12
electro-enhanced leaching
8
crvi contaminated
8
contaminated groundwater
8
electric field
8
electro-leaching system
8

Similar Publications

This work aimed at addressing the problem of hexavalent chromium pollution in the water environment, designing and preparing the Cu/CuO/NH-MIL-88B (Fe) heterojunction material with NH-MIL-88B (Fe) as the carrier, Cu/CuO was loaded on NH-MIL-88B (Fe) by light-assisted reduction. The loading of CuO effectively improves the visible light absorption capacity of the composite material. The SPR effect of Cu improves the separation and transfer of photogenerated carriers in the composite material.

View Article and Find Full Text PDF

Cellulose/covalent organic framework aerogel for efficient removal of Cr(VI): Performance and mechanism study.

Int J Biol Macromol

January 2025

Yunnan Provincial Key Laboratory of Wood Adhesives and Glued Products, Southwest Forestry University, Kunming 650224, Yunnan, China. Electronic address:

Cellulose composites have exceptional qualities, particularly in removing heavy metal ions. Nevertheless, these materials' poor mechanical qualities and the restricted exposure of surface-active sites reduce the effectiveness of their removal. The removal efficiency of adsorbent materials largely depends on their macroscopic structural characteristics.

View Article and Find Full Text PDF

Nano-Fibrillated Bacterial Cellulose Nanofiber Surface Modification with EDTA for the Effective Removal of Heavy Metal Ions in Aqueous Solutions.

Materials (Basel)

January 2025

Division of Applied Chemistry and Biochemistry, National Institute of Technology, Tomakomai College, Nishikioka 443, Tomakomai 059-1275, Hokkaido, Japan.

Nano-fibrillated bacterial cellulose (NFBC) has very long fibers (>17 μm) with diameters of approximately 20 nm. Hence, they have a very high aspect ratio and surface area. The high specific surface area of NFBC can potentially be utilized as an adsorbent.

View Article and Find Full Text PDF

Nanoscale Fe(0)-zeolite composite derived from coal bottom ash for efficient treatment of Cr(VI)-contaminated groundwater: Unveiling the importance of locations for surface-bound Fe(II) and Fe(0) passivation products.

J Hazard Mater

January 2025

Department of Civil and Environmental Engineering, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05029, Republic of Korea; Department of Environmental Engineering, Graduate School, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05029, Republic of Korea. Electronic address:

The synthesis of coal bottom ash-induced zeolite (Si-Al material) has been widely reported; however, the selective recovery of the three main elements, viz., Si, Al, and Fe, from coal bottom ash for the synthesis of reactive adsorbents has not yet been reported. In this study, we separated the magnetic and non-magnetic fractions of coal bottom ash to selectively recover Fe and Si-Al for synthesizing nanoscale zero-valent iron@zeolite (NZVI@ZBA) composites with uniform formation of Fe(0) nanoparticles on the ZBA surface.

View Article and Find Full Text PDF

Environmental concerns are driving the development of eco-friendly and effective methods for contaminant monitoring and remediation. In this study, a lanthanide porphyrin-based MOF with dual fluorescence sensing and photocatalytic properties was synthesized and applied for the detection and combined removal of Cr(VI) and ciprofloxacin (CIP). Using different excitation wavelengths, the material exhibited selective detection of Cr(VI) via fluorescence quenching and CIP through fluorescence enhancement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!