Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Aim: This study was conducted to investigate the effect of resuscitation guideline terminology on the performance of infant cardiopulmonary resuscitation (CPR).
Methods: A total of 40 intern or resident physicians conducted 2-min CPR with the two-finger technique (TFT) and two-thumb technique (TT) on a simulated infant cardiac arrest model with a 1-day interval. They were randomly assigned to Group A or B. The participants of Group A conducted CPR with the chest compression depth (CCD) target of "approximately 4 cm" and those of Group B conducted CPR with the CCD target of "at least one-third the anterior-posterior diameter of the chest". Single rescuer CPR was performed with a 15:2 compression to ventilation ratio on the floor.
Results: In both chest compression techniques, the average CCD of Group B was significantly deeper than that of Group A (TFT: 41.0 [range, 39.3-42.0] mm vs. 36.5 [34.0-37.9] mm, P = 0.002; TT: 42.0 [42.0-43.0] mm vs. 37.0 [35.3-38.0] mm, P < 0.001). Adequacy of CCD also showed similar results (Group B vs. A; TFT: 99% [82-100%] vs. 29% [12-58%], P = 0.001; TT: 100% [100-100%] vs. 28% [8-53%], P < 0.001).
Conclusions: Using the CCD target of "at least one-third the anterior-posterior diameter of the chest" resulted in deep and adequate chest compressions during simulated infant CPR in contrast to the CCD target of "approximately 4 cm". Therefore, changes in the terminology used in the guidelines should be considered to improve the quality of CPR.
Trial Registration: Clinical Research Information Service; cris.nih.go.kr/cris/en (Registration number: KCT0003486).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7092967 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0230687 | PLOS |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!