A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Differences in the performance of resuscitation according to the resuscitation guideline terminology during infant cardiopulmonary resuscitation: "Approximately 4 cm" versus "at least one-third the anterior-posterior diameter of the chest". | LitMetric

Aim: This study was conducted to investigate the effect of resuscitation guideline terminology on the performance of infant cardiopulmonary resuscitation (CPR).

Methods: A total of 40 intern or resident physicians conducted 2-min CPR with the two-finger technique (TFT) and two-thumb technique (TT) on a simulated infant cardiac arrest model with a 1-day interval. They were randomly assigned to Group A or B. The participants of Group A conducted CPR with the chest compression depth (CCD) target of "approximately 4 cm" and those of Group B conducted CPR with the CCD target of "at least one-third the anterior-posterior diameter of the chest". Single rescuer CPR was performed with a 15:2 compression to ventilation ratio on the floor.

Results: In both chest compression techniques, the average CCD of Group B was significantly deeper than that of Group A (TFT: 41.0 [range, 39.3-42.0] mm vs. 36.5 [34.0-37.9] mm, P = 0.002; TT: 42.0 [42.0-43.0] mm vs. 37.0 [35.3-38.0] mm, P < 0.001). Adequacy of CCD also showed similar results (Group B vs. A; TFT: 99% [82-100%] vs. 29% [12-58%], P = 0.001; TT: 100% [100-100%] vs. 28% [8-53%], P < 0.001).

Conclusions: Using the CCD target of "at least one-third the anterior-posterior diameter of the chest" resulted in deep and adequate chest compressions during simulated infant CPR in contrast to the CCD target of "approximately 4 cm". Therefore, changes in the terminology used in the guidelines should be considered to improve the quality of CPR.

Trial Registration: Clinical Research Information Service; cris.nih.go.kr/cris/en (Registration number: KCT0003486).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7092967PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0230687PLOS

Publication Analysis

Top Keywords

ccd target
16
"approximately cm"
12
"at one-third
12
one-third anterior-posterior
12
anterior-posterior diameter
12
diameter chest"
12
resuscitation guideline
8
guideline terminology
8
infant cardiopulmonary
8
cardiopulmonary resuscitation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!