Objective: Electrocorticogram (ECoG)-based brain-computer interfaces (BCIs) are a promising platform for the restoration of motor and sensory functions to those with neurological deficits. Such bi-directional BCI operation necessitates simultaneous ECoG recording and stimulation, which is challenging given the presence of strong stimulation artifacts. This problem is exacerbated if the BCI's analog front-end operates in an ultra-low power regime, which is a basic requirement for fully implantable medical devices. In this study, we developed a novel method for the suppression of stimulation artifacts before they reach the analog front-end.

Approach: Using elementary biophysical considerations, we devised an artifact suppression method that employs a weak auxiliary stimulation delivered between the primary stimulator and the recording grid. The exact location and amplitude of this auxiliary stimulating dipole were then found through a constrained optimization procedure. The performance of our method was tested in both simulations and phantom brain tissue experiments.

Main Results: The solution found through the optimization procedure matched the optimal canceling dipole in both simulations and experiments. Artifact suppression as large as 28.7 dB and 22.9 dB were achieved in simulations and brain phantom experiments, respectively.

Significance: We developed a simple constrained optimization-based method for finding the parameters of an auxiliary stimulating dipole that yields optimal artifact suppression. Our method suppresses stimulation artifacts before they reach the analog front-end and may prevent the front-end amplifiers from saturation. Additionally, it can be used along with other artifact mitigation techniques to further reduce stimulation artifacts.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2552/ab82acDOI Listing

Publication Analysis

Top Keywords

artifact suppression
16
stimulation artifacts
16
optimal artifact
8
analog front-end
8
artifacts reach
8
reach analog
8
suppression method
8
auxiliary stimulating
8
stimulating dipole
8
optimization procedure
8

Similar Publications

Homonuclear decoupled INADEQUATE NMR methods with improved sensitivity and resolution in solid-state NMR.

J Magn Reson

December 2024

Univ. Lille, CNRS, Centrale Lille, Univ. Artois, UMR 8181, UCCS - Unité de Catalyse et Chimie du Solide, F-59000 Lille, France. Electronic address:

The two-dimensional (2D) refocused INADEQUATE NMR experiment, which correlates double-quantum (DQ) and single-quantum (SQ) coherences, is widely used to probe the chemical connectivities in solids. Nevertheless, the multiplets along the F dimension reduce the resolution and sensitivity of this experiment. The Composite-Refocusing (CR) technique with two excitation pulses has been proposed to suppress these multiplets in 2D INADEQUATE spectra of liquids.

View Article and Find Full Text PDF

State-of-the-Art Review: Diagnosis and Management of Spinal Implant Infections.

Clin Infect Dis

December 2024

Department of Medical Microbiology and Infection Prevention, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands.

Spinal implant infections are a serious complications of instrumented spinal fusion surgeries, carrying high morbidity and complex management challenges. Early postoperative infections may manifest with wound-healing issues, back pain, and fevers. Magnetic resonance imaging (MRI) is the preferred imaging modality, but can be limited by metal artifacts.

View Article and Find Full Text PDF

This study used optical attenuation coefficient (OAC)-based optical coherence tomography (OCT) en face images to assess the ellipsoid zone (EZ) in the foveal region. This retrospective, observational, cross-sectional study of 41 healthy volunteers and 34 patients with retinal diseases included imaging data acquired using a prototype swept-source OCT system. EZ en face images were generated from OCT raster scan volumes based on OAC, followed by denoising and binarization to quantify the percentage of EZ structural normality or abnormality relative to the total imaging area.

View Article and Find Full Text PDF

The significance of bound states in the continuum (BICs) lies in their potential for theoretically infinite quality factors. However, their actual quality factors are limited by imperfections in fabrication, which lead to coupling with the radiation continuum. In this study, we present a novel approach to address this issue by introducing a merging BIC regime based on a Lieb lattice.

View Article and Find Full Text PDF

Objective: There have been many advancements in deep unrolling methods for sparse-view computed tomography (SVCT) reconstruction. These methods combine model-based and deep learning-based reconstruction techniques, improving the interpretability and achieving significant results. However, they are often computationally expensive, particularly for clinical raw projection data with large sizes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!