A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The hypoglycemia-prevention effect of sensor-augmented pump therapy with predictive low glucose management in Japanese patients with type 1 diabetes mellitus: a short-term study. | LitMetric

Aims/introduction: The predictive low glucose management (PLGM) system was introduced in March 2018 in Japan. Although there are some reports demonstrating the benefit of PLGM in preventing hypoglycemia, no data are currently available in Japanese patients with type 1 diabetes mellitus (T1DM). The aim of the present study is to evaluate the effect of PLGM with sensor-augmented pump therapy in the prevention of hypoglycemia in Japanese patients.

Materials And Methods: We included 16 patients with T1DM who used the MiniMed640G system after switching from the MiniMed620G system. We retrospectively analysed the data of the continuous glucose monitoring system in 1 month after switching to MiniMed640G.

Results: The area under the curve (AUC) of hypoglycemia of < 70 mg/dL was lowered from 0.42 ± 0.43 mg/dL day to 0.18 ± 0.18 mg/dL day ( = 0.012). Correspondingly, the duration of severe hypoglycemia (< 54 mg/dL) was reduced significantly from 15.3 ± 21.7 min/day to 4.8 ± 6.9 min/day ( = 0.019). The duration of hypoglycemia was reduced, but the reduction was not significant. Regarding the AUC for hyperglycemia > 180 mg/dL and the duration of hyperglycemia did not change. With the PLGM function, 79.3% of the predicted hypoglycemic events were avoided.

Conclusions: The hypoglycemia avoidance rate was comparable to those in previous reports. In addition, we demonstrated that PLGM can markedly suppress severe hypoglycemia without deteriorating glycemic control in Japanese T1DM patients. It is necessary to further investigate the effective use of the PLGM feature such as establishing a lower limit and the timing of resumption.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7082487PMC
http://dx.doi.org/10.1007/s13340-019-00408-7DOI Listing

Publication Analysis

Top Keywords

sensor-augmented pump
8
pump therapy
8
predictive low
8
low glucose
8
glucose management
8
japanese patients
8
patients type
8
type diabetes
8
diabetes mellitus
8
hypoglycemia-prevention sensor-augmented
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!