Cerebrovascular imaging of rodents is one of the trending applications of optoacoustics aimed at studying brain activity and pathology. Imaging of deep brain structures is often hindered by sub-optimal arrangement of the light delivery and acoustic detection systems. In our work we revisit the physics behind opto-acoustic signal generation for theoretical evaluation of optimal laser wavelengths to perform cerebrovascular optoacoustic angiography of rodents beyond the penetration barriers imposed by light diffusion in highly scattering and absorbing brain tissues. A comprehensive model based on diffusion approximation was developed to simulate optoacoustic signal generation using optical and acoustic parameters closely mimicking a typical murine brain. The model revealed three characteristic wavelength ranges in the visible and near-infrared spectra optimally suited for imaging cerebral vasculature of different size and depth. The theoretical conclusions are confirmed by numerical simulations while in vivo imaging experiments further validated the ability to accurately resolve brain vasculature at depths ranging between 0.7 and 7 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7075595PMC
http://dx.doi.org/10.1364/BOE.377670DOI Listing

Publication Analysis

Top Keywords

optoacoustic angiography
8
angiography rodents
8
signal generation
8
brain
5
whole-brain optoacoustic
4
rodents modeling
4
modeling experimental
4
experimental observations
4
observations cerebrovascular
4
imaging
4

Similar Publications

Article Synopsis
  • * However, the complexity of OA data collection and processing can lead to inconsistent methodologies among different users and developers.
  • * To address this, SKYQUANT 3D is introduced as a Python-based workflow that streamlines the analysis of 3D OA images, enabling easier batch processing, quantitative analysis, and graphical representation of results demonstrated in various preclinical and clinical tests.
View Article and Find Full Text PDF

This study highlights the potential of scanning optoacoustic angiography (OA) in identifying alterations of superficial vasculature in patients with post-thrombotic syndrome (PTS) of the foot, a venous stress disorder associated with significant morbidity developing from long-term effects of deep venous thrombosis. The traditional angiography methods available in the clinics are not capable of reliably assessing the state of peripheral veins that provide blood outflow from the skin, a key hallmark of personalized risks of PTS formation after venous thrombosis. Our findings indicate that OA can detect an increase in blood volume, diameter, and tortuosity of superficial blood vessels.

View Article and Find Full Text PDF

Purpose: Subdamaging thermal retinal laser therapy has the potential to induce regenerative stimuli in retinal diseases, but validated dosimetry is missing. Real-time optoacoustic temperature determination and control could close this gap. This study investigates a first in vivo application.

View Article and Find Full Text PDF

Deep optoacoustic localization microangiography of ischemic stroke in mice.

Nat Commun

June 2023

Institute of Pharmacology and Toxicology and Institute for Biomedical Engineering, Faculty of Medicine, University of Zurich, Zurich, Switzerland.

Super-resolution optoacoustic imaging of microvascular structures deep in mammalian tissues has so far been impeded by strong absorption from densely-packed red blood cells. Here we devised 5 µm biocompatible dichloromethane-based microdroplets exhibiting several orders of magnitude higher optical absorption than red blood cells at near-infrared wavelengths, thus enabling single-particle detection in vivo. We demonstrate non-invasive three-dimensional microangiography of the mouse brain beyond the acoustic diffraction limit (<20 µm resolution).

View Article and Find Full Text PDF

A number of optoacoustic (or photoacoustic) microscopy and mesoscopy techniques have successfully been employed for non-invasive tumor angiography. However, accurate rendering of tortuous and multidirectional neoplastic vessels is commonly hindered by the limited aperture size, narrow bandwidth and insufficient angular coverage of commercially available ultrasound transducers. We exploited the excellent flexibility and elasticity of a piezo polymer (PVDF) material to devise a fisheye-shape ultrasound detector with a high numerical aperture of 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!