The resolution revolution: Comparing spikes and high frequency oscillations in high-density and standard intra-operative electrocorticography of the same patient.

Clin Neurophysiol

Brain Center Rudolf Magnus, Department of Neurology and Neurosurgery, UMC Utrecht, P.O. Box 85500, 3508 GA Utrecht, the Netherlands; Stichting Epilepsie Instellingen Nederland, Heemstede, P.O. Box 540, 2130 AM Hoofddorp, the Netherlands.

Published: May 2020

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clinph.2020.02.006DOI Listing

Publication Analysis

Top Keywords

resolution revolution
4
revolution comparing
4
comparing spikes
4
spikes high
4
high frequency
4
frequency oscillations
4
oscillations high-density
4
high-density standard
4
standard intra-operative
4
intra-operative electrocorticography
4

Similar Publications

High resolution infrared spectra of water-CO dimers are further studied using tunable infrared sources to probe a pulsed slit jet supersonic expansion. The relatively weak transition of DO-CO in the DO ν fundamental region (≈2760 cm) is observed for the first time, as are various spectra of DO-CO. Combination bands involving the intermolecular in plane geared bend (disrotatory) mode are observed for HO-CO (≈1642, 2397 cm) in the HO ν and CO ν regions, for HDO-CO (≈2761 cm) in the HDO ν region, and for DO-CO (≈2386, 2705 and 2821 cm) in the CO ν, DO ν, and DO ν regions.

View Article and Find Full Text PDF

Liver cancer has a high mortality rate worldwide, and clinicians segment liver vessels in CT images before surgical procedures. However, liver vessels have a complex structure, and the segmentation process is conducted manually, so it is time-consuming and labor-intensive. Consequently, it would be extremely useful to develop a deep learning-based automatic liver vessel segmentation method.

View Article and Find Full Text PDF

The human ankle joint complex, consisting of calcaneus, talus, and tibia, is often simplified as a single functional ankle joint, neglecting the motion of the talus. Understanding the individual contributions of the talus and calcaneus is crucial for comprehending ankle joint complex function in healthy populations, and alterations in function that may exist in clinical conditions. To achieve accurate bone kinematics, high-resolution biplanar videoradiography was used with participants engaged in walking and running (n = 9) and hopping (n = 9) with no overlap in participants.

View Article and Find Full Text PDF

Introduction: We describe the safety of sotorasib monotherapy in patients with KRAS G12C-mutated advanced non-small cell lung cancer (NSCLC) and discuss practical recommendations for managing key risks.

Methods: Incidence rates of treatment-related adverse events (TRAEs) were pooled from 4 clinical trials: CodeBreaK 100 (NCT03600883), CodeBreaK 101 (NCT04185883), CodeBreaK 105 (NCT04380753), and CodeBreaK 200 (NCT04303780) and graded according to CTCAE v5.0.

View Article and Find Full Text PDF

Miniaturized inertial sensor based on high-resolution dual atom interferometry.

Rev Sci Instrum

January 2025

State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China.

Atom interferometry shows high sensitivity for inertial measurements in the laboratory, but it faces difficulties in field applications because of a trade-off between sensitivity and size. Therefore, there is an urgent need to develop a small sensor with high resolution for measuring acceleration and rotation in inertial navigation applications. Presented here is a miniaturized inertial sensor capable of measuring acceleration and rotation simultaneously based on high-resolution dual atom interferometers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!