AI Article Synopsis

  • Tension band wiring is a common method for treating patellar fractures but often leads to issues like wire migration and breakage; a modified technique was developed to enhance strength and reduce these risks.* -
  • A patient with a transverse fracture of the left patella underwent surgery using this new technique, which involved double tension cerclage wires for improved support.* -
  • The patient had a successful recovery with no complications, demonstrating the technique's effectiveness in promoting fracture stability and supporting quicker rehabilitation.*

Article Abstract

Rationale: Tension band wiring is the most widely accepted technique for the treatment of patellar fractures but the technique is associated with common complications like wire migration, prominence, and breakage. To reduce these complications, we developed and propose a modified technique that has a superior biomechanical strength and a potential to reduce such postoperative complications.

Patient Concerns: The patient presented with pain and mild swelling in his left knee after he slipped on the floor and fell on his left knee. He has no significant past medical or surgical history. The patient took the tension band wiring as the first choice because of the wide acceptance. But he worried about the complications.

Diagnoses: X-ray showed a transverse fracture of the left patella with an inferior pole occult fracture.

Interventions: The patient was operated with a modified technique of the classic tension band wiring for patellar fractures. In our 4-step procedure, double tension cerclage wires were wrapped under the exposed ends of the Kirschner wires (K-wires) and the tendons in figure-of-8 fashion. The aim was to increase the biomechanical strength so that when one of the tension wires fail, the other one can hold the fragments together.

Outcomes: The patient recovered very well and without any complications. The patient was followed-up for 1 year and the fracture has united very well, with satisfying knee range of motion.

Lessons: From this case study, we can detect the biomechanical advantages of our technique which can increase the stability of the fracture and that allows early functional exercise and additionally the micromotion at the fracture site has a beneficial effect of fracture union. Based on the perfect outcomes, our technique is worthy of clinical application.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7220771PMC
http://dx.doi.org/10.1097/MD.0000000000019576DOI Listing

Publication Analysis

Top Keywords

tension band
16
band wiring
16
wiring patellar
8
patellar fractures
8
modified technique
8
biomechanical strength
8
left knee
8
technique
7
fracture
6
tension
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?