Paths of the cervical instantaneous axis of rotation during active movements-patterns and reliability.

Med Biol Eng Comput

Department of Physiotherapy, Universitat de València, Carrer de Gascó Oliag, 5, E46010, Valencia, Spain.

Published: May 2020

The instantaneous helical axis (IHA) is a characteristic of neck movement that is very sensitive to changes in coordination and that has potential in the assessment of functional alterations. For its application in the clinical setting, normative patterns must be available, and its reliability must be established. The purpose of this work is to describe the continuous paths of the IHA during cyclic movements of flexion-extension (FE), lateral bending (LB), and axial rotation (AR) and to quantify their reliability. Fifteen healthy volunteers participated in the study; two repetitions were made on the same day (by different operators) and over an 8-day interval (by the same operator) to evaluate the inter-operator and inter-session reliability, respectively. The paths described by the IHA suggest a sequential movement of the vertebrae in the FE movement, with a large vertical displacement (mean, 10 cm). The IHA displacement in LB and AR movements are smaller. The paths described by the IHAs have a very high reliability for FE movement, although it is somewhat lower for LB and RA movements. The standard error of measurement (SEM) is less than 0.5 cm. These results show that the paths of the IHA are reliable enough to evaluate changes in the coordination of intervertebral movement. Graphical abstract A video photogrammetry system is used to record the cyclic movements of the neck, from which the continuous trajectories of the associated instantaneous helical axis (IHA) are calculated. We have analyzed the movements of flexion-extension (FE), lateral flexion (LB), and axial rotation (AR) for a sample of 15 healthy subjects. The measurements have been repeated with two different operators (in the same session) and in two separate sessions (same operator). IHA displacement patterns have been obtained in each movement, and the reliability of the measurement of such IHA trajectories has been estimated.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11517-020-02153-5DOI Listing

Publication Analysis

Top Keywords

instantaneous helical
8
helical axis
8
iha
8
axis iha
8
changes coordination
8
paths iha
8
cyclic movements
8
movements flexion-extension
8
flexion-extension lateral
8
axial rotation
8

Similar Publications

This study explores the synergistic effects of linoleic acid (LA) oxidation on the aggregation behavior and structural properties of wheat gluten (WG). Using lipoxygenase to induce LA oxidation, it was observed that this process significantly influenced WG's viscoelasticity and structural characteristics. Specifically, LA oxidation enhanced WG's viscoelastic properties while reducing its instantaneous elastic and recovery deformations.

View Article and Find Full Text PDF
Article Synopsis
  • Malaria sporozoites are injected by mosquitoes into mammalian skin and must navigate through dermal tissue to reach blood vessels for infection.
  • A study using collagen hydrogels as a skin model revealed that sporozoites exhibit chiral motility, typically following right-handed helical paths.
  • Sporozoites in high-concentration collagen gels move slower but travel in straighter lines, leading to more effective skin tissue exit compared to those in low-concentration gels.
View Article and Find Full Text PDF

In living and synthetic active matter systems, the constituents can self-propel and interact with each other and with the environment through various physicochemical mechanisms. Among these mechanisms, chemotactic and auto-chemotactic effects are widely observed. The impact of (auto-)chemotactic effects on achiral active matter has been a recent research focus.

View Article and Find Full Text PDF

Severe aortic valve stenosis can lead to heart failure and aortic valve replacement (AVR) is the primary treatment. However, increasing prevalence of aortic stenosis cases reveal limitations in current replacement options, necessitating improved prosthetic aortic valves. We investigate flow disturbances downstream of severe aortic stenosis and two bioprosthetic aortic valve (BioAV) designs using advanced energy-based analyses.

View Article and Find Full Text PDF

Glenohumeral biomechanics after rotator cuff (RC) tears have not been fully elucidated. This study aimed to investigate the muscle compensatory mechanism in weight-bearing shoulders with RC tears and asses the induced pathomechanics (i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!