A critical step in detection of primary intracerebral haemorrhage (ICH) is an accurate assessment of computed tomography (CT) brain images. The correct diagnosis relies on imaging modality and quality of acquired images. The authors present an enhancement algorithm which can improve the clarity of edges on CT images. About 40 samples of CT brain images with final diagnosis of primary ICH were obtained from the UKM Medical Centre in Digital Imaging and Communication in Medicine format. The images resized from 512 × 512 to 256 × 256 pixel resolution to reduce processing time. This Letter comprises of two main sections; the first is denoising using Wiener filter, non-local means and wavelet; the second section focuses on image enhancement using a modified unsharp masking (UM) algorithm to improve the visualisation of ICH. The combined approach of Wiener filter and modified UM algorithm outperforms other combinations with average values of mean square error, peak signal-to-noise ratio, variance and structural similarity index of 2.89, 31.72, 0.12 and 0.98, respectively. The reliability of proposed algorithm was evaluated by three blinded assessors which achieved a median score of 65%. This approach provides reliable validation for the proposed algorithm which has potential in improving image analysis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7067058 | PMC |
http://dx.doi.org/10.1049/htl.2018.5003 | DOI Listing |
Eur J Neurol
February 2025
IRCCS Istituto delle Scienze Neurologiche di Bologna, Department of Neurology and Stroke Center, Maggiore Hospital, Bologna, Italy.
Background: To investigate the relevance of hyperperfusion on computerised perfusion imaging (CTP) in the emergency setting in people with non-convulsive status epilepticus (NCSE) and previous stroke, to derive relevant aspects on the epileptogenic focus and the network recruited for NCSE propagation.
Methods: We enrolled consecutive adult patients with acute-onset NCSE and a previous stroke at a single institution undergoing CTP and EEG during symptoms. All patients underwent standard imaging including CT, CTP, CT angiograms and standard EEG within 30 min from hospital arrival.
Mol Genet Genomic Med
February 2025
Department of Pediatric Neurology, Hospital Universitario Quirónsalud, Madrid, Spain.
Background: Biallelic pathogenic variants in the FUCA1 gene are associated with fucosidosis. This report describes a 4-year-old boy presenting with psychomotor regression, spasticity, and dystonic postures.
Methods And Results: Trio-based whole exome sequencing revealed two previously unreported loss-of-function variants in the FUCA1 gene.
Ophthalmic Physiol Opt
January 2025
Robert O Curle Ophthalmology Suite, Institute for Regeneration and Repair, The University of Edinburgh, Edinburgh, UK.
Purpose: To determine whether imaging features derived from fundus photographs contain 3D eye shape information beyond that available from spherical equivalent refraction (SER).
Methods: We analysed 99 eyes of 68 normal adults in the UK Biobank. An ellipsoid was fitted to the entire volume of each posterior eye (vitreous chamber without the lens)-segmented from magnetic resonance imaging of the brain.
Alzheimers Res Ther
January 2025
Department of Neurology, University Medical Center Rostock, 18147, Rostock, Germany.
Background: Degeneration of the basal forebrain cholinergic system is a hallmark feature shared by Alzheimer's disease (AD) and Lewy body disease (LBD) whereas hippocampus atrophy is more specifically related to AD. We aimed to investigate the relationship between basal forebrain and hippocampus atrophy, cognitive decline, and neuropathology in a large autopsy sample.
Methods: Data were obtained from the National Alzheimer's Coordinating Center (NACC).
NMR Biomed
March 2025
Centre for Advanced Imaging, The University of Queensland, St Lucia, Queensland, Australia.
In this work, we introduce spatial and chemical saturation options for artefact reduction in magnetic resonance fingerprinting (MRF) and assess their impact on T and T mapping accuracy. An existing radial MRF pulse sequence was modified to enable spatial and chemical saturation. Phantom experiments were performed to demonstrate flow artefact reduction and evaluate the accuracy of the T and T maps.