J Biol Eng
Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695-7910 USA.
Published: March 2020
Background: In current cancer spheroid culturing methods, the transfer and histological processing of specimens grown in 96-well plates is a time consuming process. A centrifugal fluidic device was developed and tested for rapid extraction of spheroids from a 96-well plate and subsequent deposition into a molded agar receiver block. The deposited spheroids must be compact enough to fit into a standard histology cassette while also maintaining a highly planar arrangement. This size and planarity enable histological processing and sectioning of spheroids in a single section. The device attaches directly to a 96-well plate and uses a standard centrifuge to facilitate spheroid transfer. The agar block is then separated from the device and processed.
Results: Testing of the device was conducted using six full 96-well plates of fixed Pa14C pancreatic cancer spheroids. On average, 80% of spheroids were successfully transferred into the agar receiver block. Additionally, the planarity of the deposited spheroids was evaluated using confocal laser scanning microscopy. This revealed that, on average, the optimal section plane bisected individual spheroids within 27% of their mean radius. This shows that spheroids are largely deposited in a planar fashion. For rare cases where spheroids had a normalized distance to the plane greater than 1, the section plane either misses or captures a small cross section of the spheroid volume.
Conclusions: These results indicate that the proposed device is capable of a high capture success rate and high sample planarity, thus demonstrating the capabilities of the device to facilitate rapid histological evaluation of spheroids grown in standard 96-well plates. Planarity figures are likely to be improved by adjusting agar block handling prior to imaging to minimize deformation and better preserve the planarity of deposited spheroids. Additionally, investigation into media additives to reduce spheroid adhesion to 96-well plates would greatly increase the capture success rate of this device.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7066855 | PMC |
http://dx.doi.org/10.1186/s13036-020-0228-6 | DOI Listing |
Bio Protoc
March 2025
Department of Biological Sciences, Texas Tech University, Lubbock, TX, USA.
Free radicals, including reactive oxygen species (ROS) and reactive nitrogen species (RNS), induce oxidative stress. This stress plays crucial roles in cellular signaling, stress response, and disease progression, making the quantification of free radicals essential for understanding oxidative stress mechanisms. Here, we present a high-throughput fluorescence-based protocol for measuring the presence of total free radicals, including ROS and RNS, in the whole adult (fruit fly).
View Article and Find Full Text PDFBio Protoc
March 2025
Department of Biochemistry and Molecular Biology, University of Georgia, Athens, GA, USA.
Molybdenum (Mo) and tungsten (W) are elements that are utilized in biological systems. They are typically incorporated into the catalytic sites of enzymes coordinated to an organic pyranopterin cofactor; Mo may also be present in the form of a FeMo cofactor. While Mo is used by all branches of life, only a few microbes are able to utilize W.
View Article and Find Full Text PDFExp Eye Res
March 2025
School of Chemistry & Biochemistry, Georgia Institute of Technology. Electronic address:
Approximately 2-4% of adult onset and 10% of juvenile onset cases of primary open angle glaucoma can be attributed to non-synonymous coding mutations in MYOC. One of the key characteristics of a pathogenic MYOC mutant is the inability of the resulting protein to be secreted from trabecular meshwork cells. Instead, pathogenic myocilin variants accumulate in the endoplasmic reticulum.
View Article and Find Full Text PDFCell Syst
March 2025
Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104, USA; Abramson Cancer Center, University of Pennsylvania, Philadelphia, PA 19104, USA; Institute of Regenerative Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA. Electronic address:
Temperature is an important biological stimulus, yet there is a lack of approaches to modulate the temperature of biological samples in a dynamic and high-throughput manner. The thermoPlate is a device for programmable control of temperature in a 96-well plate, compatible with cell culture and microscopy. The thermoPlate maintains feedback control of temperature independently in each well, with minutes-scale heating and cooling through ΔT = 15-20°C.
View Article and Find Full Text PDFAnal Chem
March 2025
Faculty of Chemistry, Department of Food Chemistry and Toxicology, University of Vienna, 1090 Vienna, Austria.
Characterizing the chemical exposome relies on advanced instrumentation including tandem mass spectrometry coupled to liquid chromatography (LC-MS/MS), and nontargeted analysis (NTA) using high-resolution MS. However, proper sample pretreatment, balancing broad analyte coverage, method robustness, and throughput remain a major bottleneck in exposomics. Here, we developed a robust and scalable solid phase extraction (SPE) protocol for human urine and plasma and optimized it for a panel of 94 highly diverse environmental and food-related contaminants (LogP -0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!
© LitMetric 2025. All rights reserved.