suPAR is a plasma marker of chronic inflammation, and an elevated suPAR is consistently associated with worse outcome in a variety of clinical conditions. Quantification of suPAR is useful for determining patient risk in triage, but there is no fast automatized method for quick determination of suPAR. We developed and validated a rapid latex particle-enhanced turbidimetric immunoassay for quantification of plasma suPAR on the c502 and the c702 Roche Cobas® 8000 measurment systems. The turbidimetric assay was validated against the suPARnostic® ELISA (ViroGates, Denmark). This validation demonstrates suPAR can be analysed by turbidimetry giving very similar results (<15% difference) compared to the ELISA method and the observed correlations ( = 103) were strong,  > 0.95. Roche Cobas® 8000 instruments demonstrated repeatability and repoducibility, CV % at 3.4-4.1 and 5.7-11.4, respectively. The estimated limit of detection was 1.30 µg/L and 1.31 µg/L for the Cobas® c502 and c702, respectively. Dilution tests showed linearity of suPAR from 1.8 to 26.5 μg/L. The acceptable concentrations of Bilirubin, Intralipid and Hemoglobin, were 350 µmol/L, 3.3 g/L and 1.4 g/L, respectively. suPAR can be quantified reproducibly within 10 min using a turbidimetry assay. This assay is faster than ELISA with similar results, making it suitable for clinical routine analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00365513.2020.1741674DOI Listing

Publication Analysis

Top Keywords

c502 c702
12
supar
9
turbidimetric assay
8
cobas® c502
8
roche cobas®
8
cobas® 8000
8
validation supar
4
supar turbidimetric
4
assay
4
cobas®
4

Similar Publications

Preparing for another Ebola Outbreak: The impact of viral inactivation methods on commonly measured biochemistry analytes in plasma and urine.

Clin Biochem

February 2024

Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada; Department of Pathology and Laboratory Medicine, Mount Sinai Hospital, Toronto, ON, Canada. Electronic address:

Introduction: Infectious specimens containing viruses like Ebola require sample manipulation to ensure the safety of laboratory staff, which may negatively impact biochemistry test results. We evaluated the impact of viral inactivation methods on 25 biochemistry analytes in plasma, and seven biochemistry analytes in urine.

Methods: Fifteen lithium heparinized plasma specimens with and without gel underwent the following viral inactivation methods: 1) untreated, 2) Triton X-100 treatment, 2) heated for 60 min then Triton X-100 treatment, 3) heated for 60 min, 4) heated for 75 min, and 5) heated for 90 min.

View Article and Find Full Text PDF

Lack of interference of metronidazole with Roche cobas c502 and c702 chemistry tests.

Clin Biochem

August 2023

Department of Pathology and Laboratory Medicine, London Health Sciences Centre and St. Joseph's Health Care London, London, Ontario, Canada; Department of Pathology and Laboratory Medicine, Western University, London, Ontario, Canada. Electronic address:

Objective: The antibiotic metronidazole has been suggested to absorb light at a wavelength range commonly used in spectrophotometric assays. We sought to determine if any of the spectrophotometric assays used in our core laboratory would be susceptible to clinically significant interference from metronidazole in blood-based patient specimens.

Methods: Following characterization of the absorbance spectrum for metronidazole, spectrophotometric assays involving either main or subtraction wavelengths that might be susceptible to interference from metronidazole were identified.

View Article and Find Full Text PDF

Objectives: Fast and reliable ethanol assays analysis are used in a clinical context for patients suspected of ethanol intoxication. Mostly, automated systems using an enzymatic reaction based on ethanol dehydrogenase are used. The manuscript focusses on the evaluation of the performance of these assays.

View Article and Find Full Text PDF

Background: Every clinical specimen is potentially infectious, but data regarding risk for contamination of the laboratory environment during routine testing are scarce. We assessed contamination during routine sample analysis in automated clinical chemistry and microbiology laboratories.

Methods: A fluorescent marker was applied to specimen container exteriors to assess the impact of gross contamination.

View Article and Find Full Text PDF

suPAR is a plasma marker of chronic inflammation, and an elevated suPAR is consistently associated with worse outcome in a variety of clinical conditions. Quantification of suPAR is useful for determining patient risk in triage, but there is no fast automatized method for quick determination of suPAR. We developed and validated a rapid latex particle-enhanced turbidimetric immunoassay for quantification of plasma suPAR on the c502 and the c702 Roche Cobas® 8000 measurment systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!