To analyze aortic wall penetration of Heli-FX EndoAnchors after use in seal zones in the aortic arch or descending thoracic aorta during thoracic endovascular aortic repair (TEVAR). From May 2014 to May 2019, 25 patients (mean age 70.5±10 years; 16 women) were treated with TEVAR and adjunctive use of the Heli-FX device in 3 academic vascular surgery departments. Computed tomography scans were retrospectively reviewed to determine the location [arch or descending thoracic aorta (DTA)] of the EndoAnchors and the adequacy of aortic wall penetration, defined as adequate (≥2 mm), partial (<2 mm), or inadequate wall penetration (including loss). Endoleaks, reinterventions, and mortality were assessed. A total of 161 EndoAnchors were deployed (median 7 per patient, range 4-9). Twenty-two EndoAnchors were place in the arch (zones 0-2) and 139 in the DTA (zones 3-5). A larger proportion of arch deployments (27%) had suboptimal penetration compared with the DTA (6.5%; p<0.005), resulting in a 91% adequate wall penetration rate for the series overall. Three EndoAnchors were lost (and only 1 retrieved) in 3 different patients, with no additional morbidity; thus, an overall deployment success rate of 88% was achieved. At a mean follow-up of 16.6±14 months, 4 patients required 5 (successful) reinterventions, including one for a type Ia endoleak treated with chimney TEVAR. One patient died 10 months after treatment due to endograft infection, without an opportunity for surgical correction. EndoAnchors have a higher risk of maldeployment in the arch, though this may be attributable to the small learning curve experience in this location. The best aortic wall penetration for this series was in the DTA, where EndoAnchors proved useful for distal endograft fixation during TEVAR.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/1526602820907564 | DOI Listing |
Catheter Cardiovasc Interv
December 2024
Department of Surgery, University of North Dakota School of Medicine and Health Sciences, Grand Forks, North Dakota, United States.
Background: Despite advancements in valve implantation devices, vascular access complications (VAC) remain a significant cause of morbidity and mortality for those undergoing transcatheter aortic valve replacement (TAVR). We describe pre-operative imaging analysis of the aortoiliac and femoral arterial beds using the TransAtlantic intersociety consensus (TASC) score, ilio-femoral tortuosity, and procedural characteristics to identify anatomic risk factors predictive of VAC in TAVR.
Methods: Consecutive patients undergoing TAVR from 2012 to 2022 at a single North Dakota hospital were retrospectively reviewed.
J Cardiothorac Surg
December 2024
Beijing Children's Hospital Capital Medical University Beijing, Beijing, China.
Objective: Berry syndrome is a group of rare congenital cardiac malformations including aortopulmonary window (APW), aortic origin of the right pulmonary artery (AORPA), interruption of the aortic arch (IAA), patent ductus arteriosus (PDA) (supplying the descending aorta) and intact ventricular septum. This paper will analyze the clinical data of 7 patients with Berry syndrome who underwent surgical treatment in our institution and discuss the one-stage surgical correction of Berry syndrome in combination with the literature.
Methods: From January 2013 to July 2024, a total of 7 children with Berry syndrome were admitted to the Cardiac Surgery Department of Beijing Children's Hospital.
J Cardiothorac Surg
December 2024
Department of Cardiology, Thomas Jefferson University, Philadelphia, PA, 19107, USA.
Background: Right ventricular (RV) function assessment by echocardiography can be challenging due to its complex morphology. Also, increasing use of sedation rather than general anesthesia for transfemoral approach transcatheter aortic valve replacement (TAVR) reduces the need for intraoperative transesophageal echocardiography (TEE). Recent clinical studies have demonstrated the importance of 3-dimensional (3D) echocardiography and a longitudinal strain for RV function assessment.
View Article and Find Full Text PDFInt J Cardiol Heart Vasc
February 2025
Department of Radiology, Innsbruck Medical University, Innsbruck, Austria.
Background: Stroke is a feared complication after TAVI. The objective was to assess whether left atrial appendage (LAA) filling-defect (FD) patterns from early and late-phase computed tomography (CT), predict stroke/TIA in patients with severe aortic stenosis.
Methods: 124 patients with severe aortic stenosis (79.
In surgery for acute type A aortic dissection, controlling bleeding from the posterior wall of the proximal anastomosis is particularly challenging. To address this, we use the "reversed turn-up technique." For the reinforcement of the proximal aortic stump, Teflon felt strips were placed inside and outside the suture line with 4-0 polypropylene continuous transverse mattress sutures, and BioGlue was applied to the false lumen.