Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Multiple left ventricular pacing strategies have been suggested for improving response to cardiac resynchronization therapy (CRT). However, these programming strategies may sometimes entail accepting configurations with high pacing threshold and accelerated battery drain. We assessed the feasibility of predefined pacing programming protocols, and we evaluated their impact on device longevity and their cost-impact.
Methods: We estimated battery longevity in 167 CRT-D patients based on measured pacing parameters according to multiple alternative programming strategies: single-site pacing associated with lowest threshold, non-apical location, longest interventricular delay, and pacing from two electrodes. To determine the economic impact of each programming strategy, we applied the results of a model-based cost analysis using a 15-year time horizon.
Results: Selecting the electrode with the lowest threshold resulted in a median device longevity of 11.5 years. Non-apical pacing and interventricular delay maximization were feasible in most patients and were obtained at the price of a few months of battery life. Device longevity of > 10 years was preserved in 87% of cases of non-apical pacing and in 77% on pacing at the longest interventricular delay. The mean reduction in battery life when the second electrode was activated was 1.5 years. Single-site pacing strategies increased the therapy cost by 4-6%, and multi-site pacing by 12-13%, in comparison with the lowest-cost scenario.
Conclusions: Modern CRT-D systems ensure effective pacing and allow multiple optimization strategies for maximizing service life or for enhancing effectiveness. Single- or multi-site pacing strategies can be implemented without compromising device service life and at an acceptable increase in therapy cost.