To assess whether pulsed electromagnetic field therapy during cast immobilization of distal radius fractures has beneficial effects on pain and limb function, the study included 52 patients (mean age 60.8 ± 15.0 years) with distal radius fractures treated with cast immobilization. Patients were allocated to a pulsed electromagnetic field group ( = 27) or a control group ( = 25). Pain; forearm and arm circumference; range of motion; disabilities of the arm, shoulder, and hand score; and touch sensation were evaluated on the day of the plaster cast dressing and 3 and 6 weeks after. In comparison to the control group, the pulsed electromagnetic field group reported significant changes after 3 and 6 weeks of treatment: lower pain levels (=0.0052; < 0.0001, respectively), greater mobility of upper-limb joints, improvement in exteroceptive sensation, and reduction in disability of the upper limb (disabilities of the arm, shoulder, and hand) (=0.0003; < 0.0001, respectively). Our results suggest that early addition of pulsed electromagnetic field treatment, during cast immobilization of distal radius fractures, has beneficial effects on the pain, exteroceptive sensation, range of motion, and daily functioning of patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7060878PMC
http://dx.doi.org/10.1155/2020/6849352DOI Listing

Publication Analysis

Top Keywords

pulsed electromagnetic
20
electromagnetic field
20
cast immobilization
16
distal radius
16
beneficial effects
12
radius fractures
12
immobilization patients
8
immobilization distal
8
fractures beneficial
8
effects pain
8

Similar Publications

Nexus: A versatile console for advanced low-field MRI.

Magn Reson Med

January 2025

Department 8.1 - Biomedical Magnetic Resonance, Physikalisch-Technische Bundesanstalt (PTB), Braunschweig and Berlin, Germany.

Purpose: To develop a low-cost, high-performance, versatile, open-source console for low-field MRI applications that can integrate a multitude of different auxiliary sensors.

Methods: A new MR console was realized with four transmission and eight reception channels. The interface cards for signal transmission and reception are installed in PCI Express slots, allowing console integration in a commercial PC rack.

View Article and Find Full Text PDF

Background And Purpose: The objective was to examine the adjuvant effect of active pulsed electromagnetic field (PEMF) versus microwave (MW) therapy, as well as sham PEMF, in addressing pain and improving functionality for treating knee osteoarthritis (KOA).

Methods: This was a double-blind, placebo-controlled, randomized clinical trial. Individuals diagnosed with KOA were assigned to an intervention combining an exercise program (EX) with active PEMF, MW, or sham PEMF.

View Article and Find Full Text PDF

Over the past ten years, there has been an increasing demand for reliable consumer wearables as users are inclined to monitor their health and fitness metrics in real-time, especially since the COVID-19 pandemic. Reflectance pulse oximeters in fitness trackers and smartwatches provide convenient, non-invasive SpO measurements but face challenges in achieving medical-grade accuracy, particularly due to difficulties in capturing physiological signals, which may be affected by skin pigmentation. Hence, this study sets out to investigate the influence of skin pigmentation, particularly in individuals with darker skin, on the accuracy and reliability of SpO measurement in consumer wearables that utilise reflectance pulse oximeters.

View Article and Find Full Text PDF

A Review of Miniature Radio Transmitters for Wildlife Tracking.

Sensors (Basel)

January 2025

The Blavatnik School of Computer Science and AI, Tel Aviv University, Tel Aviv 69978, Israel.

This article surveys the literature on miniature radio transmitters designed to track free-ranging wild animals using emitter-localization techniques. The articles covers the topics of power sources used in such transmitters, including miniature batteries and energy harvesting, techniques for generating the transmitted radio-frequency carrier, techniques for creating short radio pulses and more general on-off schedules, modulation in modern wildlife-tracking transmitters, construction, manufacturing, and tuning techniques, and recent trends in this area. The article also describes the recreation of the first successful wildlife-tracking transmitter, a nontrivial invention that had a profound impact on wildlife ecology, and explores its behavior.

View Article and Find Full Text PDF

A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves.

Sensors (Basel)

January 2025

Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.

(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!