A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of a continuous indwelling glucometer with a point-of-care device in healthy adult horses. | LitMetric

Background: Blood glucose is tightly regulated in horses; however, since hypoglycaemia and hyperglycaemia are associated with poor prognosis, close monitoring is warranted. This study aimed at evaluating a continuous indwelling glucometer (CIG) by comparing performance with a point-of-care glucometer (POC).

Methods: Ten horses were equipped with CIG and an intravenous catheter. Interstitial glucose concentrations were determined by CIG every 5 min at rest, during insulin-induced hypoglycaemia and dextrose-induced hyperglycaemia, and compared with blood glucose determined by POC. Glucose concentrations were compared by two-way repeated measures analysis of variance and weighted kappa with Bland-Altman plots to determine agreement between assays.

Results: Horses tolerated CIG well; however, five devices had to be replaced. There were no statistically significant differences between assays at rest or during hyperglycaemia; however, during hypoglycaemia, glucose concentrations determined by CIG were significantly higher (P=0.01). The mean bias (95% limits of agreement) between assays ranged from -0.03 (-2.46 to 2.52) mmol/l (hyperglycaemia) to 0.97 (-1.23 to 3.16) mmol/l (hypoglycaemia). Assay agreement was 'good' with observed agreements of 87.04% (κ=0.67).

Conclusions Of The Study: CIG has acceptable accuracy in horses as compared with POC but overestimates glucose concentrations during hypoglycaemia and requires frequent replacement, limiting its clinical application.

Download full-text PDF

Source
http://dx.doi.org/10.1136/vr.105607DOI Listing

Publication Analysis

Top Keywords

glucose concentrations
16
continuous indwelling
8
indwelling glucometer
8
blood glucose
8
concentrations determined
8
determined cig
8
glucose
6
cig
6
horses
5
hypoglycaemia
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!