Objective: We compared 40- to 70-keV virtual monoenergetic to conventional computed tomography (CT) perfusion reconstructions with respect to quality of perfusion maps.
Methods: Conventional CT perfusion (CTP) images were acquired at 80 kVp in 25 patients, and 40- to 70-keV images were acquired with a dual-layer CT at 120 kVp in 25 patients. First, time-attenuation-curve contrast-to-noise ratio was assessed. Second, the perfusion maps of both groups were qualitatively analyzed by observers. Last, the monoenergetic reconstruction with the highest quality was compared with the clinical standard 80-kVp CTP acquisitions.
Results: Contrast-to-noise ratio was significantly better for 40 to 60 keV as compared with 70 keV and conventional images (P < 0.001). Visually, the difference between the blood volume maps among reconstructions was minimal. The 50-keV perfusion maps had the highest quality compared with the other monoenergetic and conventional maps (P < 0.002).
Conclusions: The quality of 50-keV CTP images is superior to the quality of conventional 80- and 120-kVp images.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RCT.0000000000000981 | DOI Listing |
Clin Radiol
December 2024
Department of Radiology, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, 215006, China. Electronic address:
Aim: To assess transmural remission in patients with Crohn's disease using low-dose small bowel computed tomography (CT) perfusion scans.
Materials And Methods: Forty six patients were divided into active and remission phases based on Crohn's Disease Activity Index (CDAI) and C-reactive protein (CRP). Dual-source CT enterography with low-dose perfusion scans was conducted to generate perfusion parameter maps, including blood flow (BF), blood volume (BV), time to peak (TTP), mean transit time (MTT), and permeability of surface (PS).
Eur J Surg Oncol
January 2025
UCD Centre of Precision Surgery, 47 Eccles Street, Dublin 7, Ireland; Department of Surgery, Mater Misericordiae University Hospital, Dublin, Ireland. Electronic address:
Neuroradiol J
January 2025
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA.
This study evaluates the efficacy of deep learning models in identifying infarct tissue on computed tomography perfusion (CTP) scans from patients with acute ischemic stroke due to large vessel occlusion, specifically addressing the potential influence of varying noise reduction techniques implemented by different vendors. We analyzed CTP scans from 60 patients who underwent mechanical thrombectomy achieving a modified thrombolysis in cerebral infarction (mTICI) score of 2c or 3, ensuring minimal changes in the infarct core between the initial CTP and follow-up MR imaging. Noise reduction techniques, including principal component analysis (PCA), wavelet, non-local means (NLM), and a no denoising approach, were employed to create hemodynamic parameter maps.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
January 2025
Department of Pediatric Radiology and Neuroradiology (C.D., F.A., C.P., A.R.), Children's Hospital V. Buzzi, Milan, Italy.
Glucose transporter type 1 deficiency syndrome (GLUT1-DS) is an uncommon condition represented by an infantile-onset disorder, frequently arising from heterozygous mutations in the gene. Individuals with GLUT1-DS may present with early-onset seizures (typically manifesting before 4 years of age), developmental delay, and complex movement disorders. In fewer cases, stroke-like events or hemiplegic migraine-like symptoms are also reported, defined by unilateral paresis affecting 1 side of the body and/or one-half of the face, occasionally accompanied by speech impairment.
View Article and Find Full Text PDFMAGMA
January 2025
Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany.
Objective: To establish an arterial spin labeling (ASL) protocol for rat livers that improves data reliability and reproducibility for perfusion quantification.
Methods: This study used respiratory-gated, single-slice, FAIR-based ASL imaging with multiple inversion times (TI) in rat livers. Quality assurance measures included: (1) introduction of mechanical ventilation to ensure consistent respiratory cycles by controlling the respiratory rate (45 bpm), tidal volume (10 ml/kg), and inspiration: expiration ratio (I:E ratio, 1:2), (2) optimization of the trigger window for consistent trigger points, and (3) use of fit residual map and coefficient of variance as metrics to assess data quality.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!