A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Initial anticoagulation experience with standard-dose rivaroxaban after Watchman left atrial appendage occlusion. | LitMetric

Background: Warfarin is now recommended as the standard anti-thrombotic regimen to allow complete endothelialization over the Watchman device post percutaneous left atrial appendage occlusion (LAAO). However, the need for frequent monitoring, narrow therapeutic range, dietary restrictions and multiple drug interactions associated with warfarin have contributed to increasing uptake of non-vitamin K oral anticoagulants (NOACs) worldwide. At present, the feasibility and safety of NOACs instead of warfarin post-LAAO is lacking.

Methods: Patients who underwent successful Watchman device implantation between October 1, 2016 and September 30, 2017 were enrolled in a retrospective database. And only patients who received rivaroxaban in the periprocedural period were included in this study. Transesophageal echocardiography (TEE) follow-up was scheduled at 6 weeks, at 6 months, and at 12 months post-implantation to detect device-related thrombosis (DRT) or peri-device leak. Meanwhile, thromboembolic and bleeding events were also evaluated at the time of follow-up.

Results: Totally, 57 Watchman devices were successfully implanted and 10 patients who were allocated to rivaroxaban at the dosage of 20 mg once daily were included. During the follow-up, none of the patients using rivaroxaban experienced DRT, peri-device leak, thromboembolic complications and major bleeding events, except for 2 patients who suffered minor bleeding during the 6 weeks follow-up.

Conclusions: This study suggests that a short course of standard-dose rivaroxaban following Watchman LAAO is associated with low incidence of thrombotic complications and bleeding events, and might be a feasible alternative regimen in Chinese. Further randomized trials and large sample of real-world studies are needed to validate our finding.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7048987PMC
http://dx.doi.org/10.21037/atm.2019.12.116DOI Listing

Publication Analysis

Top Keywords

bleeding events
12
standard-dose rivaroxaban
8
rivaroxaban watchman
8
left atrial
8
atrial appendage
8
appendage occlusion
8
watchman device
8
drt peri-device
8
peri-device leak
8
leak thromboembolic
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!