A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantitative assessment of near-infrared spectroscopy time course under hypercapnia using an a priori model-based fitting. | LitMetric

Background: Partial arterial pressure of carbon dioxide (CO) modulates cerebral blood flow through a vasoreactivity mechanism. Near infrared spectroscopy (NIRS) can be used to record these changes in cerebral hemodynamics. However, no laterality comparison of the NIRS signal has been performed despite being a prerequisite for the use of such a method in a vasoreactivity monitoring context. We propose to investigate the NIRS signal laterality in response to a CO-inhalation-based hypercapnia paradigm in healthy volunteers.

Methods: Eleven healthy volunteers (6 women, 5 men, mean age: 31 ± 11) underwent a 3-block-design inhalation paradigm: normoxia (5min, "baseline") - hypercapnia (2min, "stimulation") - normoxia (5min, "post-stimulation"). NIRS signal was measured using a two-channel oximeter (INVOS 5100C, Medtronic, USA) with sensors placed symmetrically on both left and right sides on each subject's forehead. Additional heart rate (HR) monitoring was performed simultaneously. Based on the NIRS mean signal pattern, an a priori model of parametric identification was applied for each channel to quantify parameters of interest (amplitude, time delay, excitation and post-stimulation time) for each inhalation block.

Results: HR increased significantly during the stimulation block. The quality of the model was satisfactory: mean absolute errors between modeled and experimental signals were lower than the resolution of the device. No significant lateralization was found between left and right values of most of the parameters.

Conclusion: Due to the lack of lateralization, this parametric identification of NIRS responses to hypercapnia could bring light to a potential asymmetry and be used as a biomarker in patients with cerebrovascular diseases.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.compbiomed.2020.103638DOI Listing

Publication Analysis

Top Keywords

nirs signal
16
normoxia 5min
8
parametric identification
8
nirs
6
quantitative assessment
4
assessment near-infrared
4
near-infrared spectroscopy
4
spectroscopy time
4
time course
4
hypercapnia
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!