Ankle fractures are some of the most common injuries seen in the emergency department. Malunited ankle fractures are uncommon. Patients with malunion frequently present with multiple complaints. Radiographs often show abnormalities in anatomical alignment. To evaluate the anatomical alignment on radiographic imaging in patients with malunited ankle fractures. Secondary aims were to evaluate patient satisfaction after reconstruction and to investigate the relationships between radiological alignment and functional outcome. All consecutive patients (n = 25) treated for a fibula malunion between January 1, 2002, and September 1, 2017, were included. The primary outcome was anatomical alignment of the ankle mortise. The talocrural angle (TCA), talar tilt (TT), and medial clear space (MCS) were used to investigate to what extent revision surgery had improved alignment. The patient-related outcome measure consisted of the Olerud and Molander Ankle Score (OMAS). To assess quality of life (QoL) the EQ-5D-5L was used. The median TCA was 78.4° before revision and 79.25° after revision; P = .297. The median TT was 2.95° before revision and 0.70° after; P < .001. The MCS before revision was 5.2 mm and 3.17 mm after; P < .000). The OMAS had a median of 67.5 points. Analysis of the QoL questionnaires yielded a score of 0.84 points. Anatomical alignment improves significantly after revision surgery of malunited ankles. Measurements of the TCA appeared less useful in determining the anatomical alignment. In our series, 60% of patients reported good to excellent results. The QoL scores of our patient were comparable to those in the healthy population in the Netherlands. Level IV: Case series.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8848054PMC
http://dx.doi.org/10.1177/1938640020910958DOI Listing

Publication Analysis

Top Keywords

anatomical alignment
20
revision surgery
12
ankle fractures
12
fibula malunion
8
malunited ankle
8
revision
7
alignment
7
ankle
5
anatomical
5
long-term follow-up
4

Similar Publications

Lisfranc Fracture-dislocation With Extensor Hallucis Brevis Tendon Interposition: A Case Report.

JBJS Case Connect

January 2025

Department of Orthopaedic Surgery, Nemours Children's Health, Wilmington, Delaware.

Case: A 14-year-old adolescent girl sustained a Lisfranc fracture-dislocation with an interposed extensor hallucis brevis (EHB) tendon. Following multiple failed attempts at closed reduction in both the emergency department and the operating room, the patient was treated in a staged manner with temporizing closed reduction and percutaneous pinning in improved alignment, followed by definitive open reduction and internal fixation once soft tissues allowed.

Conclusions: Anatomic reduction and stable fixation of Lisfranc injuries is vital to regain stability and reduce the risk of midfoot arthritis and collapse.

View Article and Find Full Text PDF

Objectives: This non-randomised clinical study aimed to identify the phenotypic characteristics that distinguish responders from non-responders. Additionally, it sought to establish a predictive model for treatment response to obstructive sleep apnoea (OSA) using mandibular advancement devices (MAD), based on the analysed phenotypic characteristics.

Material And Methods: This study, registered under identifier NCT05596825, prospectively analysed MAD treatment over 6 years using two-piece adjustable appliances according to a standardised protocol.

View Article and Find Full Text PDF

Intraoperative Augmented Reality for Vitreoretinal Surgery Using Edge Computing.

J Pers Med

January 2025

Department of Ophthalmology, Mayo Clinic, Rochester, MN 55905, USA.

: Augmented reality (AR) may allow vitreoretinal surgeons to leverage microscope-integrated digital imaging systems to analyze and highlight key retinal anatomic features in real time, possibly improving safety and precision during surgery. By employing convolutional neural networks (CNNs) for retina vessel segmentation, a retinal coordinate system can be created that allows pre-operative images of capillary non-perfusion or retinal breaks to be digitally aligned and overlayed upon the surgical field in real time. Such technology may be useful in assuring thorough laser treatment of capillary non-perfusion or in using pre-operative optical coherence tomography (OCT) to guide macular surgery when microscope-integrated OCT (MIOCT) is not available.

View Article and Find Full Text PDF

Proximal humeral fractures (PHF), ranking as the third most common osteoporotic fractures, pose a significant challenge in management. With a rising incidence in an aging population, controversy surrounds surgical versus nonoperative treatments, particularly for displaced 3- and 4-part fractures in older patients. Locking plates (LP) and proximal intramedullary nails (PHN) are primary choices for surgical intervention, but both methods entail complications.

View Article and Find Full Text PDF

Objective: The effect of different attachment positions on torque control during the labialization of maxillary lateral incisors with clear aligners was evaluated using finite element analysis.

Methods: Anatomical data acquired through cone-beam computed tomography, combined with the design of 0.625-mm-thick aligners and horizontal attachments, were integrated into the software.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!