There are still many unknowns regarding the potential application of Procalcitonin (PCT) as an adjunct to aid the diagnosis of Prosthetic Joint Infection. A systematic review searching scientific articles was performed with keywords "Procalcitonin", "Total Hip Replacement", and "Total Knee Replacement" (n=123). After review of the abstract and full text for relevance, ten articles were included (n=10). Serum PCT levels for chronic Total Hip Replacement (THR) and Total Knee Replacement (TKR) have a range of mean values from 1.5 ng/ml to 14.2 ng/ml. Specificity ranges from 0.27 to 0.98, while sensitivity is from 0.33 to 0.9. On primary THR/TKR with confirmation of non-infected status, serum PCT peaks between 1-3 days post-operatively, with peak levels varying from 0.12 - 0.79 ng/ml. Based on this review, serum PCT is not a good adjunct in diagnosing Prosthetic Joint Infection (PJI). Synovial fluid PCT fluid may add better clinical support but requires further studies. There were several limitations with this review: the studies are small and heterogeneous, there was a variable definition of PJI, and there was a wide range of mean values, sensitivity and specificity.
Download full-text PDF |
Source |
---|
Sci Rep
December 2024
Department of Orthopedic Surgery, The First Hospital of Hebei Medical University, NO. 89 Donggang Road, Shijiazhuang, 063000, Hebei, P. R. China.
The risks and benefits associated with simultaneous bilateral unicompartmental knee arthroplasty (UKA) continue to engender contentious debate. The aim of this study was to compare the clinical outcomes of simultaneous bilateral and unilateral UKA. A retrospective review was performed between 2019 and 2022 on 280 patients (130 simultaneous bilateral vs.
View Article and Find Full Text PDFJ Bone Joint Surg Am
October 2024
Musculoskeletal Tumor Center, Department of Orthopedics, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, People's Republic of China.
Background: Pelvic reconstruction after type I + II (or type I + II + III) internal hemipelvectomy with extensive ilium removal is a great challenge. In an attempt to anatomically reconstruct the hip rotation center (HRC) and achieve a low mechanical failure rate, a custom-made, 3D-printed prosthesis with a porous articular interface was developed. The aim of this study was to investigate the clinical outcomes of patients treated with this prosthesis.
View Article and Find Full Text PDFmBio
December 2024
Department of Biological Sciences, University of Notre Dame, Notre Dame, Indiana, USA.
Unlabelled: The bacterium is an opportunistic pathogen that can cause lung, skin, wound, joint, urinary tract, and eye infections. While is known to exhibit a robust competitive response toward other bacterial species, this bacterium is frequently identified in polymicrobial infections where multiple species survive. For example, in prosthetic joint infections, can be identified along with other pathogenic bacteria including , , and .
View Article and Find Full Text PDFPerm J
December 2024
School of Medicine and Health Sciences, The George Washington University, Washington, DC, USA.
Introduction: Hip hemiarthroplasty is a surgical procedure that requires the adhesion of the prosthetic implant by utilizing a fixation technique, either cemented or noncemented. The current literature does not provide a clear recommendation on a superior technique, although many countries outside the US have guidelines recommending cemented over noncemented procedures. Further, surgeon perceptions and beliefs related to the cemented and noncemented techniques in hip arthroplasty fractures are generally unknown.
View Article and Find Full Text PDFClin Orthop Relat Res
October 2024
Rush Copley Medical Center, Aurora, IL, USA.
Background: Polymethylmethacrylate (PMMA) antibiotic-laden bone cement (ALBC) is commonly used in total joint arthroplasty to treat and potentially prevent prosthetic joint infection (PJI). Multiple properties impact the elution characteristics of antibiotics from PMMA-based ALBC, including viscosity. What is not known is how medium-viscosity cement formulations affect antibiotic elution and how different cement products from different manufacturers compare regarding reaching the minimum inhibitory concentration (MIC) of antibiotics for common PJI-causing organisms in an in vitro setting.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!