Background: The aim of the study was to compare the accuracy of percutaneous pedicle screw (PPS) insertion (P-side) with that of conventional open screw insertion (O-side) during unilateral open transforaminal lumbar interbody fusion (TLIF) in the same patients. We also sought to determine the incidence of pedicle screw misplacement and to identify relevant risk factors.

Methods: The study was a retrospective analysis of prospectively collected data for 766 pedicle screws placed in 181 consecutive patients who underwent a unilateral open-TLIF procedure in the lumbosacral spine. Our minimally invasive TLIF was performed by unilateral open freehand insertion of pedicle screws for decompression on one side and PPS on the opposite side. Using this approach, we were able to compare the accuracy of PPS insertion with that of conventional open screw insertion in the same patients. There were 383 PPSs and 383 screws inserted by the open method. The accuracy of screw placement was evaluated on reconstructed computed tomography images obtained postoperatively, and screw misplacement was classified. Potential risk factors for screw misplacement were investigated in three-level mixed-effects logistic regression analysis.

Results: Thirty-four screws (8.9%) were misplaced on the P-side and 37 (9.5%) were misplaced on the O-side; the difference was not statistically significant (P = 0.803). Subclassification analysis revealed minor perforation of 28 screws (7.3%) on the P-side and 32 (8.4%) on the O-side, moderate perforation of 5 screws (1.3%) on the P-side and 4 (1.0%) on the O-side, and severe perforation of 1 screw (0.3%) on each side. Three-level mixed-effects logistic regression analysis identified body mass index as a significant risk factor for screw misplacement on the P-side (odds ratio 1.194, 95% confidence interval 1.066-1.338).

Conclusions: Accuracy of pedicle screw insertion was not significantly different between PPS insertion and conventional open screw insertion in the same patients. Body mass index had a significant influence on the risk of screw misplacement in PPS insertion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7071703PMC
http://dx.doi.org/10.1186/s12891-020-3180-1DOI Listing

Publication Analysis

Top Keywords

screw insertion
20
screw misplacement
20
pedicle screw
16
conventional open
16
pps insertion
16
screw
13
unilateral open
12
open screw
12
insertion
10
accuracy pedicle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!