A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Biological Monitoring of Occupational Exposure to Metals in Electric Steel Foundry Workers and Its Contribution to 8-Oxo-7,8-Dihydro-2'-Deoxyguanosine Levels. | LitMetric

In this study, the urinary concentrations of selected metals in workers from an electric steel foundry in Tunisia were assessed and compared with existing biological limit values and general population reference values. Moreover, the association between oxidative DNA damage, measured as urinary 8-oxo-7,8-dihydro-2'deoxyguanosine (8-oxodG) and co-exposure to metals and polycyclic aromatic hydrocarbons (PAHs) was evaluated. Urinary levels of 12 metals were determined by inductively coupled plasma-mass spectrometry (ICP-MS) in end-shift spot samples from 89 workers. The urinary levels of phenanthrene (U-PHE), as marker of exposure to PAHs, and 8-oxodG were also available. Median levels ranged from 0.4 µg/L (cobalt, Co, and thallium, Tl) to 895 µg/L (zinc, Zn). Only 1% of samples was above the biological limit values for Co, and up to 13.5% of samples were above limit values for Cd. From 3.4% (Co) to 72% (lead, Pb) of samples were above the reference values for the general population. Multiple linear regression models, showed that manganese (Mn), Zn, arsenic (As), barium (Ba), Tl, and Pb were significant predictors of 8-oxodG (0.012 ≤ ≤ 0.048); U-PHE was also a significant predictor (0.003 ≤ ≤ 0.059). The variance explained by models was low (0.11 ≤ R ≤ 0.17, < 0.005), showing that metals and PAHs were minor contributors to 8-oxodG. Overall, the comparison with biological limit values showed that the study subjects were occupationally exposed to metals, with levels exceeding biological limit values only for Cd.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7142962PMC
http://dx.doi.org/10.3390/ijerph17061811DOI Listing

Publication Analysis

Top Keywords

limit values
20
biological limit
16
≤ ≤
12
electric steel
8
steel foundry
8
values general
8
general population
8
reference values
8
urinary levels
8
values
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!