There is limited evidence supporting a replacement interval of infusion sets for continuous subcutaneous insulin infusion (CSII). The aim of this study was to investigate if steel and soft cannula infusion sets can be used in CSII therapy for up to 7 days without negative impact on infusion sites or glycemic control. The insulin infusion sets YpsoPump Orbitmicro (steel needle) and YpsoPump Orbitsoft (soft cannula) were each used for up to 7 days by 40 adult subjects with CSII. Each subject used both infusion set types twice. Early replacement reasons were documented and glycemic control was monitored. Of 160 inserted insulin infusion sets, 66% were used for 7 days with no obvious difference between steel and soft infusion sets. The mean wearing time was 6.2 ± 1.5 days. Main reasons for early infusion set replacements were occlusions (19%), plaster issues (4%), and accidental pull-out (4%). Comparing glycemic control during day 1-3 and 1-7, mean glucose was 146 ± 21 mg/dL versus 148 ± 18 mg/dL, coefficient of variation was 34% ± 7% versus 33% ± 5%, and insulin dose was 40 ± 11 U versus 41 ± 11 U. Only mild and nonserious infusion site reactions occurred. In this study, 7 days indwelling time of insulin infusion sets did not show a clinically relevant impact on glycemic control or insulin requirements and the infectious risk appeared to be low. The replacement interval of infusion sets may be individualized beyond the currently labeled maximum use duration.

Download full-text PDF

Source
http://dx.doi.org/10.1089/dia.2019.0445DOI Listing

Publication Analysis

Top Keywords

infusion sets
28
insulin infusion
20
glycemic control
20
infusion
13
infusion set
12
early replacement
8
replacement reasons
8
impact glycemic
8
replacement interval
8
interval infusion
8

Similar Publications

Prevention of viral transmission must be assured before re-use of infusion sets.

Eur J Anaesthesiol

January 2025

From the Unit of Infection Prevention and Control, Department of Clinical Microbiology, Sahlgrenska University Hospital, Gothenburg, Sweden (RA, IQ), Department of Infectious Diseases, Institute of Biomedicine, Sahlgrenska Academy, Gothenburg University, Gothenburg, Sweden (RA), Department of Infection Prevention, Oslo University Hospital, Oslo, Norway (EL), Department of Infection Prevention and Control, Region Stockholm (AT), Department of Medicine Solna, Karolinska Institutet, Solna, Sweden (AT).

View Article and Find Full Text PDF

Reply to 'Prevention of viral transmission must be assured before re-use of infusion sets'.

Eur J Anaesthesiol

January 2025

From the Department of Anaesthesia, SV Hospital Group, Institute of Clinical Sciences at the Sahlgrenska Academy, University of Gothenburg, Gothenburg (SLK, MVG, PWM), Department of Infection Prevention and Control, Södra Älvsborg Hospital, Borås (JEW), Department of Infectious Disease, Institute of Biomedicine at the Sahlgrenska Academy, University of Gothenburg, Gothenburg (JEW) and Anaesthesiology and Intensive Care, Department of Clinical Sciences Lund, Lund University, Lund, Sweden (PB).

View Article and Find Full Text PDF

Background: Although commercially developed automated insulin delivery (AID) systems have recently been approved and become available in a limited number of countries, they are not universally available, accessible, or affordable. Therefore, open-source AID systems, cocreated by an online community of people with diabetes and their families behind the hashtag #WeAreNotWaiting, have become increasingly popular.

Objective: This study focused on examining the lived experiences, physical and emotional health implications of people with diabetes following the initiation of open-source AID systems, their perceived challenges, and their sources of support, which have not been explored in the existing literature.

View Article and Find Full Text PDF

Disposable intravenous infusion sets as a temporary intravascular shunt for major limb replantation: a retrospective study.

Langenbecks Arch Surg

December 2024

Department of Plastic Reconstructive Surgery & Hand Microsurgery, Ningbo No. 6 Hospital, Ningbo, Zhejiang, China.

Objective: The key to increasing the success rate of limb preservation lies in timely restoration of the blood supply to the severed limb, This study examines the clinical effect of a disposable intravenous infusion device as a temporary vascular shunt device which can quickly restore blood circulation in the replantation of severed limbs.

Methods: A retrospective review of all amputated major limbs in our department from May 2005 to May 2022. Patients treated with intravenous infusion tubes as temporary vascular shunt devices were included in group A(shunt group ) and those who could not use temporary intravascular shunt devices were included in group B (no shunt group).

View Article and Find Full Text PDF

Background: The addition of intravenous dexamethasone can significantly prolong analgesia and reduce opioid-related side effects after brachial plexus blockade, but the most effective administration time is yet unknown. The objective of this study is to determine if the timing of administration of dexamethasone affects the duration of analgesia after supraclavicular brachial plexus block.

Methods: This is a double-blind, placebo-controlled, randomized trial performed at a single-center, tertiary academic health sciences center.

View Article and Find Full Text PDF